摘要
介绍了西霞院水电站发电机电压配电装置的选择方案,重点对厂用分支回路采用大容量高速开关组合保护装置FSR、主变低压侧汇流母线采用大电流共箱封闭母线的设计特点进行了概述。
The paper introduces the Selection Scheme of generator voltage distribution equipment in Xixiayuan Hydropower Station, focusing on auxiliary circuit adopts FSR which has high short circuit breaking capacity, and low voltage side of main transformer adopts common enclosure bus with high current. All the above design characteristics are summarized in the paper.
出处
《电气技术》
2014年第12期110-112,135,共4页
Electrical Engineering
关键词
FSR
高分断
大电流
共箱母线
FSR
high short circuit breaking capacity
high current
common enclosure bus