期刊文献+

张家口电厂6号机胶球清洗系统改造与运行效果 被引量:2

Reconstruction and Operation Effects of Silica Gel Ball Cleaning System of No.6 Unit of Zhangjiakou Power Plant
下载PDF
导出
摘要 张家口发电厂6号机(300MW)的胶球清洗装置采用自旋转均布投球、旋转自清洁固定二次滤网和收球网、胶球自动计数等新技术进行改造,经试验测试和运行优化后投球率为20%,每分钟平均胶球循环率为100%,5分钟收球率达98%,水阻达到DLT581-95的要求,采用的硅胶胶球寿命可达半年以上,冬季可正常运行。对比试验表明,机组真空平均提高0.65k Pa,年平均节煤1.63gce/(k W·h),年节能效益165万元。 Ball Cleaning System of No. 6 Unit (300MW) of Zhangjiakou Power Plant, Datang International Company was reconstructed with new technologies, including auto gyrating device distributing balls uniformly, fixed secondary filter net and ball colleting net with a function of rotation and self-cleaning, automatic silica gel ball counter, etc. With experimental test and operating optimization, the ball launching rate is 20%, the average silica gel ball cycling rate per minute is 100%, the ball recycling rate every five minute is 98%, hydraulic resistance meets the requirement of DLT581 - 95, the life the lifespan of silica gel balls is over half a year. The reconstructed system could operate normally in winter. The contrasting experiment shows that the average vacuum of the Electric Generator 6 increases 0.65kPa in average, coal saving is 1.63gce/( kW . h) per year in average, the energy-saving benefit is RMB 1.65 million.
出处 《汽轮机技术》 北大核心 2014年第6期451-454,460,共5页 Turbine Technology
基金 国家发改委"2013年低碳技术创新及产业化示范工程"项目
关键词 胶球清洗 投球率 收球率 胶球循环率 均布投球 silica gel ball cleaning ball launching rate ball recycling rate silica gel ball cycling rate Uniformdistribution of balls
  • 相关文献

同被引文献12

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部