期刊文献+

尿液分析仪检验结果与镜检结果的分析 被引量:5

The Analysis of Contrast Urine Analyzer Test Results and the Results of Examination
下载PDF
导出
摘要 目的通过对尿液分析仪检验与尿沉渣镜检的结果分析,发现尿液分析仪检验的不足之处,寻找改进方法提高尿检质量。方法选择我院1500例患者晨尿阴性标本为研究对象,采用尿液分析仪检验和尿沉渣镜检方法同时进行晨尿标本检测与分析。结果 1500例晨尿阴性标本中,尿液分析仪干化学潜血结果高于镜检结果 ;尿液分析仪干化学白细胞结果较镜检结果低;尿液分析仪干化学蛋白质结果较镜检结果高;沉渣镜检管型阴性干化学阳性;尿液分析仪干化学结晶阴性,镜检阳性一个"+"号,其他项目检测结果与沉渣结果基本相符。结论尿分析仪检测干扰因素较多,检验人员做好质量检测,同时建立尿沉渣镜检复查标准和结果审核制度,从而提高临床诊断结果。 Objective Urine analyzer and urine sediment examination of the results of analysis,we found deficiencies urine analyzer test,urine test to find improved methods to improve quality. Methods 1500 cases of patients in our hospital morning urine samples negative for the study, the use of urine analyzer and urine sediment examination methods simultaneously morning urine specimens and analyzed. Results 1500 cases of negative morning urine specimens,urine analyzer dry chemical occult blood results above examination results; urine dry chemistry analyzer results are compared with microscopic examination of the results of a low white blood cell; urine dry chemistry analyzer results are compared with microscopic protein results high; sediment microscopy casts negative dry chemical was positive; urine Analyzer dry chemical crystallization negative microscopy positive a + sign,test results and other items sediment results are basically consistent. Conclusion Urine analyzer interference factors,inspectors do quality testing,while establishing review criteria and results of urine sediment examination audit system, thus improving the clinical diagnosis.
作者 张晶秋
出处 《中国卫生标准管理》 2015年第1期32-34,共3页 China Health Standard Management
关键词 尿液分析仪检验 尿沉渣镜检 影响因素 Urine analyzer test Urinary sediment microscopy Factors affecting
  • 相关文献

参考文献3

二级参考文献9

共引文献9

同被引文献24

引证文献5

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部