期刊文献+

预应力预制框架节点修复机理试验研究 被引量:2

REHABILITATION MECHANISM STUDY OF BEAM-TO-COLUMN CONNECTIONS FOR SELF-CENTERING POST-TENSIONED PRECAST FRAME
原文传递
导出
摘要 基于工程可修复及震后快速修复的需求,提出一种新型自复位预应力预制框架节点形式(PTED节点)。为了研究PTED节点的抗震性能,进行低周往复加载试验,试验结果表明,节点的弹塑性变形集中在耗能角钢上,梁、柱构件及预应力筋基本保持弹性,卸载后节点具有良好的自复位能力,残余变形小。基于PTED节点的自复位功能及损伤集中的特点,提出PTED节点的修复机理和修复方法,即震后利用预应力筋的回弹复位功能使结构恢复到正常状态,然后更换受损角钢完成修复。为了验证修复机理的正确性和修复方法的可行性,对修复后节点重新进行低周往复加载,试验结果表明,修复后节点的抗震能力与原节点基本等同。 Based on the requirement of quick rehabilitation , a new kind of the self-centering post-tensioned precast connection ( named PTED ) was proposed .The tests of the PTED frame connections were carried out .The damage and mechanical characteristics of the connections under low reversed cyclic loading were studied .The results showed that the damage concentrates in the steel angles , the connections have the ability of self-centering and the residual deformation is small when unloading . Based on the self-centering capability of the PTED connection , the rehabilitation mechanism and the repair method were proposed , that is, after the earthquake the joint can returned to it’ s original position utilizing the self-centering capability of the post-tensioned steel and then just replace the damaged angle .The tests of the repaired PTED connection under low reversed were carried out and the repaired method was verified .The results showed that the seismic capacity of the repaired joint was basically the same as the original one .
出处 《工业建筑》 CSCD 北大核心 2014年第9期56-61,共6页 Industrial Construction
基金 江苏省自然科学基金(BK20130408) 淮海工学院自然科学基金(KXZ2012004) 淮海工学院引进人才科研启动基金(KQ12021)
关键词 自复位 修复 角钢 预应力 低周往复荷载 self-centering rehabilitation steel angle prestress low reversed cyclic loading
  • 相关文献

参考文献12

  • 1GB50011-2010,建筑抗震设计规范[S]. 被引量:1847
  • 2周颖,吕西林.摇摆结构及自复位结构研究综述[J].建筑结构学报,2011,32(9):1-10. 被引量:227
  • 3吕西林,陈云,毛苑君.结构抗震设计的新概念——可恢复功能结构[J].同济大学学报(自然科学版),2011,39(7):941-948. 被引量:278
  • 4Shen Qiang, Yahya C Kurama. Nonlinear Behavior of Posttensioned Hybrid Coupled Wall Subassemblages [ J] Journal of Structural Engineering, 2002, 128 (10) : 1290 - 1300. 被引量:1
  • 5Yahya C Kurama, Shen Qiang. Posttensioned Hybrid Coupled Walls under Lateral Loads [J]. Journal of Structural Engineering, 2004, 130(2) :297 -509. 被引量:1
  • 6Shen Qiang, Yahya C Kurama. Seismic Design and Analytical Modelling of Pasttensioned Hybrid Coupled Wall Subassembladges [ J]. Journal of Structural Engineering, 2006, 132 (7) : 1030 - 1040. 被引量:1
  • 7Brad D Weldon, Yahya C Kurama. Nonlinear Behavior of Preeast Concrete Coupling Beams under Lateral Loads [ J ]. Journal of Structural Engineering, 2007, 133 ( 11 ) : 1571 - 1581. 被引量:1
  • 8Englekirk R E. Design-Construction of the Paramount : A 39-Story Precast Prestressed Concrete Apartment Building [ S ]. PC! Journal, 2002, 47(4) : 56 -71. 被引量:1
  • 9StefanoPampanin,KimSeeber,李晨光.预应力预制混凝土结构体系抗震性能研究新进展[C]∥第七届全国预应力结构理论与工程应用学术会议.南京:2012. 被引量:1
  • 10潘振华,潘鹏,叶列平,邱法维.自复位钢框架节点有限元模拟及参数分析[J].建筑结构学报,2011,32(3):35-42. 被引量:62

二级参考文献83

  • 1JGJ101-1996,建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1997 被引量:102
  • 2GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010. 被引量:947
  • 3Bruneau M, Uang C M, Whittaker A. Ductile design of steel structures [ M ]. New York: McGraw-Hill, 1988. 被引量:1
  • 4Federal Energency Management Agency. Interim guidelines: evaluation, repair, modification and design of welded steel moment frame structures[ R]. Washington DC : Federal Emergency Management Agency, 1995. 被引量:1
  • 5Ricles J, Sause R, Garlock M, Zhao C. Posttensioned seismic-resistant connections for steel frames [J]. Journal of Structural Engineering, 2001,127 (2) : 113- 121. 被引量:1
  • 6Garlock M, Sause R, Ricles J. Behavior and design of post-tensioned steel frame systems [J]. Journal of Structural Engineering, 2007,133 (3) : 389-399. 被引量:1
  • 7Christopoulos C, Filiatrauh A, Uang C M, Folz B. Posttensioned energy dissipating connections for moment-resisting steel frames [ J ]. Journal of Structural Engineering, 2002, 128(9) : 1111-1120. 被引量:1
  • 8Ricles J, Sause R, Garlock M, Zhao C. Posttensioned seismic-resistant connections for steel frames [ J ]. Journal of Structural Engineering, 2001,127 ( 2 ) : 113-121. 被引量:1
  • 9Hyung-Joon Kim, Constantin Christopoulos. Friction damped posttensioned self-centering steel moment- resisting frames [ J ]. Journal of Structural Engineering, 2008,134 (11) : 1768-1779. 被引量:1
  • 10Prakash V, Powell G H, Campbell S. DRAIN-2DX-static and dynamic analysis of inelastic plane structures [ M ]. California: National Information Service for Earthquake Engineering, EERC, 1993. 被引量:1

共引文献2401

同被引文献10

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部