在对变电站低压侧采用传统LC电力滤波器治理谐波充分调研的基础上,建议将有源电力滤波器(APF)运用于低压侧进行谐波治理,突出介绍了APF相对于LC的优势,建立了APF主电路拓扑结构及主电路、控制算法、检测法数学模型,最后进行了MATLAB仿真试验。理论分析和仿真结果均表明:APF在可控性、响应速度、自适应能力、安全性及同电网的兼容性方面均优于LC滤波器,拥有良好的动静态性能。
In the low-voltage side of the substation power filter using basic traditional LC harmonic pollution control,this paper proposes the active power filter(APF) used in the low-pressure side of the harmonic ideas of governance, highlighting the relative APF strengths in LC,and establishes the APF main circuit topology and the main circuit,control algorithms,mathematical models detection method,and finally the MATLAB simulation.
出处
《工业控制计算机》
2014年第10期143-145,共3页
Industrial Control Computer