期刊文献+

粉末综合性质表征在质量源于设计(QbD)中的应用 被引量:1

Application of Powder Characterisation to Implementation of Quality by Design(QbD)
原文传递
导出
摘要 通过研究粉针制剂的气流分装过程,探讨如何建立固体粉末的粉体学性质和粉针制剂产品分装质量的定量关系,以确定影响气流分装的关键因素,并通过质量源于设计的理念解决实际生产中的问题。 The behavior of powder for injection during the vacuum filling process had been systematically investigated in this paper,and key powder properties which influenced the filling weight variation were identified.This study revealed how real processing challenges in pharmaceutical industry could be successfully resolved by using the quality by design (QbD) concept,based on acquired correlation between powder properties and real performance in the production.
出处 《中国医药工业杂志》 CAS CSCD 北大核心 2014年第11期1086-1089,共4页 Chinese Journal of Pharmaceuticals
关键词 质量源于设计 气流分装 流动性 粉针制剂 quality by design vacuum filling flowability powder for injection
  • 相关文献

参考文献12

  • 1Yu LX. Pharmaceutical quality by design: product and process development, understanding, and control [J]. Pharm Res, 2008, 25 (4): 781-791. 被引量:1
  • 2Chen C. Implementing quality by design: ONDQA initiatives [EB/OL]. http://www.fda.gov/ohrms/dockets/ac/O6/slides/ 2006-4241sl 7.ppt. 被引量:1
  • 3ICH. Pharmaceutical Development [EB/OL]. http://www. ich.org/products/guidelines/quality/article/quality-guidelines. html. 被引量:1
  • 4U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research (CDER), et al. Guidance for industry: PAT - A framework for innovative pharmaceutical development, manufacturing and quality assurance [EB/OL]. http://www. fda.gov/downloads/Drugs/Guidances/ucm070305.pdf. 被引量:1
  • 5Hinz DC. Process analytical technologies in the pharma- ceutical industry: the FDA's PAT initiative [J] Anal Bioanal Chem, 2006, 384 (5) : 1036-1042. 被引量:1
  • 6Bowles N, Cahill E, Haeberlin B, et al. Application of quality by design to inhalation products [J]. RDD Europe, 2007, 1: 61-69. 被引量:1
  • 7Freeman R. Measuring the flow properties of consolidated, conditioned and aerated powders -- A comparative study us- ing a powder rheometer and a rotational shear cell [J]. Pow- der Technol, 2007, 174 (1-2) : 25-33. 被引量:1
  • 8Schwedes J. Review on testers for measuring flow properties of bulk solids [J]. GranulMatter, 2003, 5 (1) : 1-43. 被引量:1
  • 9Ghoroi C, Gurumurthy L, McDaniel D J, et al. Multi-faceted characterization of pharmaceutical powders to discern the influence of surface modification [J]. Powder Technol, 2013, 236: 63-74. 被引量:1
  • 10Krantz M, Zhang H, Zhu J. Characterization of powder flow: Static and dynamic testing [J]. Powder Technol, 2009, 194 (3) : 239-245. 被引量:1

同被引文献2