油纸绝缘系统弛豫响应极化谱函数建模研究 被引量:3

Study on relaxation response polarization spectrum function modeling of oil-paper insulation system
原文传递
导出
摘要 根据绝缘介质弛豫响应特性推导了油纸绝缘系统的集中参数等值电路.将该等值电路转化为运算电路分析,并运用电路叠加定理构建油纸绝缘弛豫响应极化谱的函数表达式,得到了极化谱的复合指数衰减模型.其中各指数衰减项的时间常数为运算电路极点值的负倒数,并且复合的项数与油纸绝缘介质内部弛豫机构数密切相关.模型的提出可以为后续油纸绝缘弛豫响应的拓扑建模奠定基础.再利用该模型对相同电压等级,不同容量、不同运行年限油浸式电力变压器的测试极化谱采用非线性最小二乘方法进行拟合,拟合结果进一步验证了极化谱模型的准确性. According to the dielectric relaxation response lumped parameter equivalent circuit of oil-paper insulation system was deduced.The equivalent circuit can be converted to operational circuit,on that basis by using circuit superposition theorem function expression of relaxation response polarization spectrum of oil-paper insulation was built,so that the composite exponential attenuation model of the polarization spectrum was got.Among them the exponential decay time constants are negative reciprocal of operational circuit extreme values,and the number of composite item is closely related with oil-paper insulation internal relaxation mechanisms.The model proposed can lay the foundation for subsequent oil-paper insulation relaxation response topology modeling.At last,fit the test polarization spectrum of oil-immersed power transformers with different capacity and running years by using nonlinear least square method,and the fitting results verify the accuracy of the polarization spectrum model.
出处 《福州大学学报(自然科学版)》 CAS CSCD 北大核心 2014年第5期713-718,共6页 Journal of Fuzhou University(Natural Science Edition)
基金 国家自然科学基金资助项目(61174117)
关键词 油纸绝缘 极化谱 弛豫响应 集中参数 运算电路 复合指数衰减模型 oil-paper insulation polarization spectrum relaxation response lumped parameters operational circuit composite exponential attenuation model
  • 相关文献

参考文献12

  • 1刘刚..变压器油-纸绝缘状态诊断的回复电压法研究[D].重庆大学,2008:
  • 2Urbani G M, Brooks R S. Using the recovery voltage method to evaluate aging in oil - paper insulation[ C ]//IEEE International Conference on Conduction and Breakdown in Solid Dielectrics. Stockholm: IEEE, 1998:93 -97. 被引量:1
  • 3Mitchinson P M, Lewin P L, Chen G C, et al. An experiment for evaluating the scale effect of moisture on high voltage trans- former insulation [ C ]//Conference Record of the 2006 IEEE International Symposium on Electrical Insulation. Toronto: IEEE, 2006 : 218 - 221. 被引量:1
  • 4Yao Z T, Saha T K, Darveniza M. A new approach to interpret the results of return voltage measurements on aged power trans- formers [ J]. Journal of Electrical & Electronics Engineering, 2000, 20( 1 ) : 1 -6. 被引量:1
  • 5Nouruddeen B, Hussein A. Diagnosis of XLPE cable using the recovery voltage measurement method[ C]//5th Student Confer- ence on Research and Development. Selangor: IEEE, 2007:1 -4. 被引量:1
  • 6高宗宝,吴广宁,周利军,刘君,吕玮,赵虎.水份含量对变压器油纸绝缘系统回复电压参数影响规律的研究[J].高压电器,2011,47(4):37-41. 被引量:37
  • 7Ekanayake C. Application of dielectric spectroscopy for estimating moisture content in power transformers [ D ]. Stockholm : Chalmers University of Technology, 2003. 被引量:1
  • 8金维芳.电介质物理学[M].北京:机械工业出版社,1997.. 被引量:20
  • 9JonscherAK.固体中的介电弛豫(影印版)[M].西安:西安交通大学出版社,2008. 被引量:1
  • 10JonscherAK.普适弛豫定律(影印版)[M].西安:西安交通大学出版社,2008. 被引量:1

二级参考文献11

  • 1KALOCSAL L. Spectrum of polarization phenomena of long time-constant as a diagnostic method of oil-paper insulation system [C]//Proceeding of the 3rd International Conference on Properties and Application of Dielectric Materials.Japan :IEEE Dielectrics and Electrical Insulation Society and Institute of Electrical Engineers of Japan, 1991:723-726. 被引量:1
  • 2NEMETH E.Measuring voltage response:A non-destructive diagnostic test method of HV insulation[J]. IEEEProceeding of Science, Measurement and Technology, 1999, 146(5) : 249-252. 被引量:1
  • 3HASSANL O,BORSIL H, GOCKENBACH E. Diagnostic of insulation condition of oil impregnated paper insulation system with return voltage measurements [C]//2003 Annual Report Conference on Electrical insulation and Dielectric Phenomena, USA : IEEE, 2003 : 153-156. 被引量:1
  • 4BLUE R, UqTAMCHANDANI D, FARISH O.Determination of FFA concentration in transformer oil by fluorescence measurements[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 1998(5) : 892-895. 被引量:1
  • 5PAHLAVANPOUR W B.Analysis of transformer oil for transformer condition monitoring[C]//IEE Colloquium on An Engineering Review of Liquid Insulation, London:IEE, 1997 : 1-5. 被引量:1
  • 6ASCHENBRENNER V, UCIK T.Using of parameter of RVM measurement of qualitative appreciation of power transformer insulation state [C] // Transmission and Distribution Conference and Exhibition, Asia:IEEE, 2002 : 1829-1833. 被引量:1
  • 7YAO Z T, SAHA T K.Separation of ageing and moisture impacts on transformer insulation degradation by polarization measurements[C]//Proceedings of the CIGRE 2002 Paris Session, Paris : CIGRE, 2002 : 26-30. 被引量:1
  • 8刘敏.不同含水量对油纸绝缘老化速率的影响[J].绝缘材料,2008,41(3):40-42. 被引量:16
  • 9张涛,蔡金锭.应用极化谱分析油纸变压器绝缘纸板水分含量的研究[J].电工电能新技术,2009,28(4):46-49. 被引量:19
  • 10刘刚,廖瑞金,冯运,唐超,周天春,杨华云.温度对变压器油纸绝缘系统回复电压参数影响规律的研究[J].高压电器,2010,46(1):80-84. 被引量:30

共引文献55

同被引文献30

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部