脉氧监护仪在先天性心脏病筛查中的应用 被引量:3

The value of Masimo SET in the diagnosis of congenital heart disease
下载PDF
导出
摘要 目的:观察脉氧监护仪(Masimo Signal Extraction Technology, Masimo SET)在先天性心脏病筛查中的灵敏度及准确性。方法:选择2011年1月-2013年7月生后24 h内入住新生儿病房的256名新生儿为筛查对象,排除存在家族性遗传病、传染病、窒息、脐带异常、胎盘异常、严重贫血者。于生后48~72 h之间通过Masimo SET检测血氧饱和度,并对所有新生儿行心超检查确认。结果:256例新生儿中筛查阳性18例,阴性238例。经心超确认阳性病例中16例、阴性病例中10例为先天性心脏病,经统计学处理差异有显著性(P〈0.05)。Masimo SET检测先天性心脏病的敏感性为88.89%,特异性为95.79%。结论:Masimo SET对新生儿早期筛查先天性心脏病有较大的帮助。 Objective:To evaluate the sensitivity and accuracy of the pulse oxygen monitor (Masimo SET) in the screening of congenital heart disease. Methods:Two hundred and iffty-six babies born in 24 hours during January 2011 to July 2013 in our department were chosen for screening, excluding the presence of familial hereditary diseases, infectious diseases, asphyxia, abnormality of umbilical cord, placenta and severe anemia. Oxygen saturation in blood was assayed with Masimo SET within 48~72 hours after birth and echocardiography was performed to all the babies. Results:There were 18 positive cases and 238 negative cases in 256 neonates based on the screening of Masimo SET and later 16 cases of congenital heart diseases were conifrmed by echocardiography in positive group and 10 cases in negative group. The differences were statistically significant (P〈0.05). The sensitivity for Masimo SET to screen congenital heart disease was 88.89% with the specificity 95.79%. Conclusion:Masimo SET is of beneift to screening congenital heart disease in early stage of neonates.
出处 《上海医药》 CAS 2014年第19期41-42,73,共3页 Shanghai Medical & Pharmaceutical Journal
关键词 新生儿 先天性心脏病 Masimo SET 筛查 Masimo SET newborns congenital heart disease Masimo SET screening
  • 相关文献

参考文献8

  • 1Kemper AR, Mahle WT, Martin GR, et al. Strategies for implementing screening for critical congenital heart disease [J]. Pediatrics, 2011, 128(5): e1259-e1267. 被引量:1
  • 2闻大翔,杭燕南.脉搏氧饱和度监测的新技术—MasiITlo信号萃取技术[J].中国医学装备,2004,1(2):20-23. 被引量:4
  • 3闻大翔,周颖,王珊娟,杭燕南.体动和低灌注影响脉搏血氧饱和度准确性的临床研究[J].临床麻醉学杂志,2004,20(6):333-335. 被引量:10
  • 4杭燕南 ... ..当代麻醉学[M],2002.
  • 5Barker S J, Shah NK. The effects of motion on the performance of pulse oximeters in volunteers [J]. Anesthesiology, 1997, 86(1): 101-108. 被引量:1
  • 6Durbin CG, Rostow SK. More reliable oximetry reduces the frequency of arterial blood gas analysis and hastens oxygen weaning following cardiac surgery: a prospective randomizedtrial of the clinical impact of a new technology [J]. Critical Care Med, 2002, 30(8): 1735-1740. 被引量:1
  • 7Erler T, Avenarius S, Wichniewski E, et al. Longevity of masimo and nellcor pulse oximeter sensors in the care of infants [J]. Perinatol, 2003, 23(2): 133-135. 被引量:1
  • 8朱晓伟.tadalafil[J].国外医学(药学分册),2003,30(2):125-125. 被引量:266

二级参考文献10

  • 1Barker SJ, Novak S, Morgan S. The performance of three pulse oximeters during low perfusion in volunteers. Anesthesiology, 1997, 87: 409. 被引量:1
  • 2Lichtenthal PR, Wade LD. Evaluation of signal extraction technology(SET) in preventing false alarms when using pulse oximetry in the recovery room. Anesth Analg, 1996, 82 (Suppl 2): 278. 被引量:1
  • 3Barker SJ, Morgan S. Effects of motion on the performance of seventeen pulse oximeters. Presented at the Society of Technology in Anesthesiology Annual Meeting. January, 2000. 被引量:1
  • 4Bohnhorst B, Peter CS, Poets CF. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a convention and two new generation oximeters. Clinical Care Med, 2000, 28 : 1565-1568. 被引量:1
  • 5杭燕南,庄心良,蒋豪,主编.当代麻醉学.上海科学技术出版社, 2002. 1089-1095. 被引量:1
  • 6Dumas C,Wahr J,Tremper KK. Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room. Anesth Analg, 1996, 83 : 269-272. 被引量:1
  • 7Malviya S, Reynolds PI, Voepel-Lewis M, et al. False alarms and sensitivity of conventional pulse oximetry versus the Masimo SET technology in the pediatric postanesthesia care unit.Anesth Analg, 2000, 90 : 1336-1340. 被引量:1
  • 8Barker SJ, Shah NK. The effects of motion on the performance of pulse oximeters in volunteers. Anesthesiology, 1997, 86 : 101-108. 被引量:1
  • 9Trivedi NS, Shah NK, Jacobsen BP, et al. Failure rate of pulse oximeters during various motions.Anesthesiology,1994, 81: 504. 被引量:1
  • 10Barker SJ, Shah NK, Hyatt J, et al. Pulse Oximetry and motion artifact: a study of accuracy and reliability.Anesthesiology, 1995, 83: 452. 被引量:1

共引文献276

同被引文献19

  • 1Kuelling B, Arlettaz Mieth R, Bauersfeld U, et al. Pulse oximetry screening for congenital heart defects in Switzerland: Most but not all maternity units screen their neonates [J]. Swiss reed weekly, 2009, 139(47 -48) :699 -704. 被引量:1
  • 2Kemper A R, Mahle W T, Martin G R, et al. Strategies for implementing screening for critical congenital heart disease [J]. Pediatrics, 2011,128 ( 5 ) : e1259 -e 1267. 被引量:1
  • 3Swenson A K, Brown D, Stevermer J J. PURLs: Pulse oximetry for newborns: should it be routine ? [J] J Fam Pract, 2012,61 ( 5 ) : 283 -286. 被引量:1
  • 4Riede F T, Wmer C,Dnert, et al. Effectiveness of neonatal pulse oximetry screening for detection of critical congenital heart disease in dally clinical routine-results from a prospective multicenter study [J]. Eur J Pediatr,2010,169(8) :975-981. 被引量:1
  • 5Zhao Q M, Ma X J, Ge X L,et al. Pulse oximetry with clinical assessment to screen for congenital heart disease in neonates in China: a prospective study[J]. Lancet,2014,384(9945) :747-754. 被引量:1
  • 6Rosychuk R J, Hudson-Mason A, Eldund D, et al. Discrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants [J]. Neonatology ,2012,101 ( 1 ) : 14-19. 被引量:1
  • 7Castillo A, Deulofeut R, Critz A,et al. Prevention of refinopathy of prematurity in preterm infants through changes in clinical practice and S002 technology[J]. Acta Paediatrica.2011.100(2 ) :188-192. 被引量:1
  • 8仇黎生,刘锦纷,徐志伟,朱丽敏,徐卓明.新生儿先天性心脏病术后早期心排血量评估及死亡原因分析[J].中华胸心血管外科杂志,2010,26(1):1-4. 被引量:10
  • 9潘素娇,林爱琳,陈美云.彩色多普勒超声检测正常小儿心脏瓣膜反流情况[J].实用儿科临床杂志,1999,14(2):101-102. 被引量:3
  • 10黄灿,农绍汉,陈寄梅,何少茹,陈萍,丁以群,岑坚正,许刚.体外循环时血氧分压对婴幼儿发绀型先天性心脏病S-100β蛋白与神经元特异性烯醇化酶的影响[J].中华儿科杂志,2012,50(2):121-125. 被引量:6

引证文献3

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部