间隙自补偿漏风控制系统在空气预热器密封改造中的应用 被引量:5

Application of gap self-compensating air leakage control system in air preheater seal reformation
下载PDF
导出
摘要 回转式空气预热器漏风率较高是一直困扰各大发电企业的难题,它严重影响着机组的经济运行。哈尔滨兴隆锅炉有限公司采用一种全新的漏风控制技术——间隙自补偿漏风控制系统,在湖北能源集团鄂州发电有限公司#3机组大修期间对空气预热器进行了密封改造。改造后,机组在满负荷及变负荷运行的情况下,漏风率长期保持在4%~5%,保证了机组的经济运行。 The larger air leakage rate of the rotary air preheater is difficulty troubling many large power generation enterprises,and it influences on unit economic operation seriously. Using a new air leakage control technology —— the gap self-compensating air leakage control system,the Harbin Xinglong Boiler Company Limited implemented the air preheater seal reformation of unit No. 3 in Ezhou Power Generation Company limited of Hubei Energy Group during the unit overhaul period. After reformation,under unit full load and variable load conditions,the air leakage rate remained within 4% ~ 5% for long term,and the unit economic operation was ensured.
出处 《华电技术》 CAS 2014年第8期21-23,77,共3页 HUADIAN TECHNOLOGY
关键词 空气预热器 密封改造 间隙自补偿漏风控制系统 效果 效益 air preheater seal reformation gap self-compensating air leakage control system effect benefit
  • 相关文献

参考文献4

  • 1应静良,李永华主编,国家电力公司电力机械局等编..电站锅炉空气预热器[M].北京:中国电力出版社,2002:231.
  • 2袁德.现代电站锅炉技术及其改造[M].北京:中国电力出版社.2006. 被引量:4
  • 3王明春.火电机组回转式空预器漏风控制系统[J].东南大学学报(自然科学版),1998,28(a11):65-68. 被引量:4
  • 4中国动力工程学会.火力发电设备技术手册:第4卷[M].北京:机械工业出版社,2001. 被引量:1