超声造影在乳腺局灶性腺病诊断中的应用价值 被引量:9

Value of contrast-enhanced ultrasound in the diagnosis of the local adenosis of breast
原文传递
导出
摘要 目的 分析乳腺局灶性腺病的超声造影表现,探讨超声造影在乳腺腺病诊断及鉴别诊断中的应用价值.方法 回顾性分析110例经手术病理证实的乳腺腺病患者的常规超声及超声造影资料,观察记录肿块的超声造影特征,分析肿块的造影增强模式、边界特征及时间-强度曲线.结果 110例中常规超声检出151个病灶,诊断为腺病或腺病瘤61例,诊断符合率40.4%(61/151).超声造影诊断为腺病或腺病瘤106例,诊断符合率70.2%(106/151),高于常规超声.实时超声造影增强特点为:在造影剂灌注达峰时,103个病灶(68.2%)以整体或部分不均匀增强为主.121个病灶(80.1%)增强程度以中等增强或稍高增强为主,少数病灶(11.9%,18/151)显示为明显高增强,极少数病灶(7.9%,12/151)为低增强.107个病灶(70.9%)在造影剂灌注达峰时边界欠清晰,无包膜,与周围背景乳腺组织具有一定的延续性,其中5个病灶在增强后其体积较常规超声显示明显增大,4个病灶在造影剂灌注达峰时边界似呈毛刺状,无规律性;29.1%(44/151)的病灶边界较清晰.在高增强和等增强的病灶中,时间强度曲线形态以“同进同出型”(60/151,39.7%)和“快进快出型”(65/151,43.0%)为主.结论 乳腺局灶性腺病的超声造影图像有一定特征,通过超声造影可以对乳腺腺病的诊断及鉴别诊断提供更多的依据,有助于提高超声诊断信心. Objective To analyse appearances of contrast-enhanced ultrasound(CEUS) of breast local adenosis,and to explore the value of CEUS in the diagnosis of the local adenosis of breast.Methods The data of conventional ultrasound and CEUS of local adenosis of breast in 110 cases confirmed by operation and pathology were analysed.The enhancement patterns,border of the lesion,time-intensity curve were evaluated respectively.Results Totally 151 lesions were detected by conventional ultrasound in 110 cases,61 lesions were diagnosed by conventional ultrasound for adenopathy or adenosis tumor,the diagnosis coincidence rate was 40.4% (61/151).By CEUS,106 lesions were diagnosed as adenopathy or adenosis tumor,the diagnosis coincidence rate was 70.2 % (106/151),higher than that of conventional ultrasound.The features of CEUS include:In contrast perfusion time to peak,103 lesions inhomogeneously enhanced in whole or in part (68.2 %).The enhancement degree of 121 lesions (80.1 %) were moderate enhancement or slightly high enhancement,a few lesions (11.9%,18/151) showed significantly enhanced,and very few lesions (7.9 %,12/151) for low enhancement.In contrast perfusion peak,107 (70.9 %) lesions had less clear boundary,no envelope,and had a certain continuity with the surrounding background breast tissue,in which 5 lesions were showed significantly increased in size by CEUS comparison with conventional ultrasound,and the boundary of 4 lesions was shaped like the burr,no regularity after enhancing.The boundary of 29.1% (44/151) of the lesion was clear.In the lesions with moderate enhancement or slightly high enhancement,the time-intensity curve mainly displayed "same washin and same wash out" (60/151,39.7 %) and "fast washin and fast wash-out" (65/151,43.0%).Conclusions CEUS image of focal breast adenosis has certain characteristics.CEUS can provide more evidences in diagnosis and differential diagnosis of breast adenosis,which can help to improve diagnostic con
出处 《中华超声影像学杂志》 CSCD 北大核心 2014年第8期686-689,共4页 Chinese Journal of Ultrasonography
关键词 超声检查 微气泡 乳腺纤维囊性病 Ultrasonography Microbubbles Fibrocystic breast disease
  • 相关文献

参考文献10

二级参考文献16

  • 1方华,李凤华,夏建国,王筱玲,许桂英,唐韵.实时灰阶超声造影在乳腺肿瘤诊断中的应用研究[J].中国超声医学杂志,2007,23(6):423-425. 被引量:38
  • 2Foster FS,Burns PN,Simpson DH,et al.Ultrasound for the sualization and quantification of tumor microcirculation.Cancer and Metastasis Reviews,2000,19(122):131-138. 被引量:1
  • 3Cosgrove D.Microbubble enhancement of tumour neovasculatity.Eur Radiol,1999,9(Suppl 3):413-414. 被引量:1
  • 4Jung EM,Jungius KP,Rupp N,et al.Contrast enhanced harmonic ultrasound for differentiating breast tumors-first results.Clin Hemorheol Microcirc,2005,33(2):109-120. 被引量:1
  • 5Ricci P,Cantisani V,Ballesio L,et al Benign and maligant breast lesions:efficacy of real time contrast-enhanced ultrasound vs magnetic resonance imaging.Ultrasound Med,2007,28(1):57-62. 被引量:1
  • 6Yang WT,Tse GM,Lam PK,et al.Correlation between color power Doppler sonographic measurement of breast tumour vasculature and immunohistochemical analysis of microvessel density for the quantitation of angiogenesis.J Ultrasound Med,2002,21(11):1227-1235. 被引量:1
  • 7武汉医学院病理学教研室,中山医学院病理学教研组编著.外科病理学.第一版.武汉:湖北人民出版社,1983.816-817 被引量:1
  • 8Weinreb JC, Newstead G. MR imaging of the breast. Radiology,1995,196:593 被引量:1
  • 9Palmowski M, Lederle W, Gaetjens J, et al. Comparison of conventional time-intensity curve vs maximum intensity over time for post-processing of dynamic contrast-enhanced ultrasound. Eur J Radiol, 2010,75 : e149-e153. 被引量:1
  • 10汪晓虹,王怡,许萍,富丽娜,王意达.乳腺良恶性病灶的实时灰阶超声造影征象研究[J].中国医学计算机成像杂志,2010,16(3):246-249. 被引量:34

共引文献63

同被引文献68

引证文献9

二级引证文献95

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部