期刊文献+

拉萨老城区传统民居采暖能耗及室内热环境分析 被引量:2

Indoor Thermal Environment and Energy Consumption of Traditional Building in Lhasa Historic District
下载PDF
导出
摘要 以拉萨老城区典型传统民居为研究对象,对其在电采暖工况下的室内热环境和耗热量进行了计算机模拟,并与参照建筑对比。结果表明,传统建筑的耗热量明显大于参照建筑,同时采暖耗热强度高于拉萨远期采暖热指标;在采暖温度为18℃时,传统建筑室内热环境整体上不能达到相关标准所规定的热舒适要求;室内空气温度与围护结构内表面平均辐射温度的温差较大,可能对室内热舒适产生不利影响。在分析传统建筑围护结构失热分布情况后,提出了适宜于拉萨传统建筑节能改造的建议。 The indoor thermal environment and heat consumption in traditional building in Lhasa under electric heating are examined by simulation, compared with the reference building. The results show that the indoor thermal environment cannot reach the standards when heating setpoint is 18 ℃, the difference between air temperature and MRT is above comfort band and the heat consumption is significantly higher than the reference building. And sustainable retrofitting measures are suggested, which meet both energy efficiency and historic preservation.
作者 黄凌江 兰兵
机构地区 武汉大学建筑系
出处 《建筑节能》 CAS 2014年第8期1-7,共7页 BUILDING ENERGY EFFICIENCY
基金 国家自然科学基金:西藏传统聚落空间营造的气候响应技术策略及其评价(50908181) 遗产保护视角下西藏寺院殿堂室内气候评价与控制(51278525)
关键词 拉萨 传统建筑 采暖 室内热环境 耗热量 节能改造 Lhasa traditional dwelling heating indoor thermal environment heat consumption retrofitting