摘要
为检验机组一次调频功能,对亭子口水电站机组进行了一次调频试验。在确保机组安全稳定运行的情况下,测试并确定一组一次调频运行参数以满足机组一次调频性能要求,确保电网及发电机组安全运行,使并网运行机组随时适应电网负荷和频率的变化,提高电能质量及电网频率的控制水平。
In order to examine the performances of primary frequency regulation of turbine-generator units in Tingzikou Hydropower Station, the primary frequency regulation tests are carried out. Under the premise of ensuring the safe and stable operation of units, a set of primary frequency regulation operating parameters are tested and determined. These parameters can meet the requirements of primary frequency regulation, guarantee the safe operation of power grid and turbine-generator units, ensure unit operation adapting to the changes of power grid in load and frequency at any time, and improve the control on power quality and power grid frequency.
出处
《水力发电》
北大核心
2014年第9期63-66,共4页
Water Power
关键词
机组
一次调频
调速器
调节参数
亭子口水电站
turbine-generator unit
primary frequency regulation
governor, adjustable parameter
Tingzikou Hydropower Station