摘要
以西安某城市广场为例,介绍其平面布局和防火分区及人员疏散方面的消防设计难点。探讨了城市综合体人员疏散安全性分析评估的方法,提出了不能满足安全性要求时的修正办法,并且分析了影响安全疏散的相关因素,对于城市综合体做好日常安全管理,消防部门更好地开展监督有一定指导意义。
Taking a square in Xi'an as an example, the layout and fire compartmentation, as well as fire design problems on evacuation were introduced. The evaluation method of city complex safety evacuation was discussed, and the correction method when the safety requirement can't be satisfied was put forward. And the related factors influencing the safety evacuation were analyzed too. The paper can help with daily safety management of city complex, and the fire department supervision.
出处
《消防科学与技术》
CAS
北大核心
2014年第8期892-894,共3页
Fire Science and Technology
关键词
城市综合体
安全疏散
安全评估
city complex
safety evacuation
safety evaluation