在对发电厂、变电站接地网腐蚀现象进行调研的基础上指出了接地网防腐蚀的重要性 ;对接地网腐蚀机理进行了探讨 ,对接地网腐蚀的影响因素进行了分析 ;
Based on investigation to the situation of serious corrosion of several grounding grids,importance of anti corrosion for grounding grid was pointed out.Mechanism of grounding grid corrosion was discussed and the factors effecting corrosion of grounding grid were analyzed.Several anti corrosion steps of grounding grid were analyzed briefly.
出处
《湖北电力》
2002年第3期31-34,共4页
Hubei Electric Power
关键词
接地网
腐蚀
防护
过电压保护
soil
substation
grounding grid
corrosion and protection