期刊文献+

高强度聚焦超声照射正常离体心肌组织的实验研究——局部心肌的凝固损伤范围与声辐照剂量的关系 被引量:3

An experimental study of in-vitro myocardial tissue exposed to high-intensity focused ultrasound irradiation: the relationship between the lesion extent and the acoustic dosage
原文传递
导出
摘要 目的 探讨高强度聚焦超声 (HIFU)非侵入性凝固局部心肌组织的能量 -效应关系。方法 采用不同强度 (110 0 0W /cm2 、15 80 0W /cm2 和 2 2 2 0 0W /cm2 )的HIFU ,在不同辐照时间 (1s、3s、5s和 8s)的作用下 ,对 2 0只正常猪离体心脏进行定位损伤 ,观察并测定损伤区的形态及体积 ,损伤区及其与周围正常组织交界处的组织同时送病理学检查。结果 不同剂量下HIFU所致的损伤体积范围分布在 (11.2± 1.9)mm3 ~(2 83 .2± 4.5 )mm3 之间 ,不同处理因素间的损伤体积差异具有显著性意义 (P <0 .0 5 )。损伤形态随剂量增大趋向不规则。组织学观察可见损伤区与周围正常组织分界明显。结论 HIFU可有效地使心肌组织发生凝固性坏死 。 Objective To explore the dose effect relation of swine in vitro myocardial tissue exposed to high intensity focused ultrasound (HIFU).Methods The JC therapeutic apparatus was separately used to selectively destroy the different parts in myocardial tissue of 20 fresh normal swine in vitro hearts which just treated by a vacuum pump.In the step,the tissue was exposed to HIFU with the acoustic intensity of 11 000 W/cm 2, 15 800 W/cm 2 and 22 200 W/cm 2 respectively for 1 s,3 s,5 s and 8 s.The autopsy was applied and then the lesions were measured,and pathologic changes were observed with a microscope.Results The lesion volume varied from ( 11.2 ± 1.9 )mm 3 to ( 283.2 ± 4.5 )mm 3 with the change of exposed time and acoustic intensity,and significant difference was found among them (P< 0.05 ).Marked pathologic changes in regional myocardial tissue were observed by microscope when the in vitro myocardial tissue had been exposed to HIFU.Conclusions HIFU technology is effective to obtain in vitro ablation of myocardial tissue.The shape of lesion area appeared irregular with increased HIFU dose.
出处 《中华超声影像学杂志》 CSCD 2002年第5期295-299,共5页 Chinese Journal of Ultrasonography
基金 国家自然科学基金资助 (30 1 70 2 65)
关键词 高强度聚焦超声 心肌 剂量效应关系实验 Highi ntensity focused ultrasound Myocardium Dose response relationship
  • 相关文献

参考文献2

二级参考文献3

共引文献156

同被引文献33

  • 1熊六林,黄晓波,费兴波,于晋生,玉秋红,薛卫成,郑珠颖,王晓峰.高强度聚焦超声辐照猪胰腺实验研究[J].中华医学超声杂志(电子版),2007,4(1):15-18. 被引量:9
  • 2陈灏珠.实用心脏内科学[M]上海:上海科学技术出版社,2007524-592827-830. 被引量:1
  • 3H(a)ker A,Michel MS,Marlinghaus E. Extracorporeally induced ablation of renal tissue by high-intensity focused ultrasound[J].British Journal of Urology International,2006,(04):779-785.doi:10.1111/j.1464-410X.2006.06037.x. 被引量:1
  • 4Wu F,Wang ZB,Cao YD. Changes in biologic characteristics of breast cancer treated with high-intensity focused ultrasound[J].Ultrasound in Medicine and Biology,2003,(10):1487-1492. 被引量:1
  • 5Margreiter M,Marberger M. Focal therapy and imaging in prostate and kidney cancer:high-intensity focused ultrasound ablation of small renal tumors[J].Journal of Endocrinology,2010,(05):745-748. 被引量:1
  • 6Fischer K,Gedroyc W,Jolesz FA. Focused ultrasound as a local therapy for liver cancer[J].Cancer,2010,(02):118-124. 被引量:1
  • 7Rowland IJ,Rivens I,Chen L. MRI study of hepatic tumors following high int ensity focused ultrasound surgery[J].British Journal of Radiology,1997,(02):144-153. 被引量:1
  • 8Wiart M,Curiel L,Gelet A. Influence of perfusion on highintensity focused ultrasound prostate ablation:a first-pass MRI study[J].Magnetic Resonance in Medicine,2007,(01):119-127. 被引量:1
  • 9Fujisaki M,Chiba T,Enosawa S. Cardiac intervention using high-intensity focused ultrasound:creation of interatrial communication in beating heart of an anesthetized rabbit[J].Ultrasound in Obstetrics and Gynecology,2010,(05):607-612. 被引量:1
  • 10Mitnovetski S,Almeida AA,Goldstein J. Epicardial high-intensity focused ultrasound cardiac ablation for surgical treatment of atrial fibrillation[J].Heart Lung and Circulation,2009,(01):28-31. 被引量:1

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部