摘要
通过对镇海炼油化工股份有限公司炼油厂热电站Y- 130 / 39- 1锅炉安全阀异常动作的分析 ,指出了该型号锅炉蒸汽系统存在的隐患 。
An analysis of the abnormal actuation of a U-130/39-1 boiler safety valve installed at the refinery thermal power station of Zhenhai Petrochemical Co. Ltd. has exposed the hidden peril of this type of boiler safety valve system. To cope with this, proper modification measures are proposed.
出处
《热能动力工程》
CAS
CSCD
北大核心
2002年第2期207-208,共2页
Journal of Engineering for Thermal Energy and Power