期刊文献+

330MW对冲锅炉炉内流场模拟及实验研究 被引量:11

Numerical and Experimental Investigation of Flow Field in A 330MW Opposed Firing Boiler
下载PDF
导出
摘要 应用 k-ε双方程模型对对冲燃烧炉内的流场进行了数值模拟。计算结果显示 :该种类型锅炉的前后墙对冲燃烧方式有效解决了炉膛出口烟气的温度偏差问题 ,使水平烟道过热器、再热器超温爆管的可能性与四角切圆锅炉相比大大降低 ,并与实验结果吻合。图 5表 1参 In this paper, the flow field in opposed firing boiler is numerically simulated by means of k ε two equations model. The simulation results indicate that the opposed firing way in this kind of boiler solves efficiently the problem of the temperature deviation at the furnace exit, which decreases greatly the possibility of tube rupture of the superheater and reheater in horizontal flueway due to exceedingly high temperature compared with that of the tangentially fired furnace. And the numerical results represent the experimental ones well. Figs 5, table 1 and refs 5.
出处 《动力工程》 CSCD 北大核心 2002年第3期1772-1775,1811,共5页 Power Engineering
关键词 330MW对冲锅炉 流场模拟 k-ε双方程模型 烟道 温度偏差 四角切向锅炉 opposed firing boiler k ε two equations model temperature deviation in horizontal flueway
  • 相关文献

参考文献5

  • 1陶文铨编著..数值传热学[M].西安:西安交通大学出版社,1988:721.
  • 2Patankar S V 张政(译).传热与流体流动的数值计算[M].北京:科学出版社,1984.. 被引量:2
  • 3孙平.600MW电站锅炉炉内多相流动、传热、燃烧过程及炉内污染、结渣的数值试验研究,浙江大学博士论文[M].,1999.. 被引量:1
  • 4岑可法 樊建人.工程气固多向流动理论及计算[M].浙江大学出版社,.. 被引量:1
  • 5浙江省电力试验研究所.台州电厂7号炉大修后通风试验报告[M].,1998,5.. 被引量:1

共引文献1

同被引文献72

引证文献11

二级引证文献64