摘要
本文通过与美国、英国相关标准规定的对比 ,及对国内外的灭火试验数据的分析 ,阐述了我国现行《低倍数泡沫灭火系统设计规范》对非水溶性液体固定顶储罐泡沫混合液供给强度与连续供给时间的合理性 。
Based on the comparison of the related standards of USA and UK as well as the analysis of the fire test data at home and abroad, the paper discusses the appropriation of the foam solution supply intensity and duration of non-water soluble fixed roof tank regulated in 'Code for Design of Low-expansion Foam Extinguishing System'. It provides materials for understanding and mastering the provisions of the code for the code users.
出处
《消防科学与技术》
CAS
2002年第3期41-43,共3页
Fire Science and Technology
关键词
供给强度
供给时间
非水溶性液体
固定顶储罐
泡沫混合液
non-water soluble liquid
fixed roof tank
foam solution supply intensity
supple duration