期刊文献+

在肝门静脉成像检查中重复应用3.0 T MR NATIVE TrueFISP序列的可行性研究 被引量:1

Feasibility research of repetitive application of 3.0TMRNATIVETrueFISP sequence in hepatic portal vein imaging detection
下载PDF
导出
摘要 目的:研究在肝门静脉成像检查中重复应用3.0 T MR NATIVE TrueFISP序列的可行性。方法:以2017年1月至3月期间滨州医学院附属医院招募的14名健康志愿者为研究对象。在相同的血流抑制翻转时间(BSP-TI)下,应用3.0TMRNATIVETrueFISP序列先后对这14名志愿者进行2次肝门静脉成像检查(两次检查的间隔时间为1~2周),然后对2次获取图像中肝门静脉及肝门静脉分支的显示情况进行主观评分,并计算其肝门静脉主干(MPV)、左支(LPV)、右支(RPV)图像的信噪比(SNR)和对比噪声比(CNR)。结果:这14名志愿者均成功地完成2次肝门静脉成像检查,均获得较为满意的图像。对这14名志愿者进行2次检查的结果显示,其图像中肝门静脉及肝门静脉分支显示情况的主观评分、肝门静脉MPV、LPV、RPV图像的SNR和CNR相比,P>0.05。结论:在肝门静脉成像检查中重复应用3.0 T MRI NATIVE TrueFISP序列的可行性良好。 objective: to study the feasibility of repeated application of 3.0t MR NATIVE TrueFISP sequence in hepatic portal vein imaging. Methods: 14 healthy volunteers recruited by binzhou medical college affiliated hospital from January to March 2017 were selected as the research objects. In inhibiting reverse blood flow to the same time(BSP-TI), the application of 3.0 T MR NATIVE TrueFISP sequence has 2 times to the 14 volunteers hepatic portal vein imaging(check twice time interval of 1 ~ 2 weeks), and then 2 times to get the image display profile of hepatic portal vein and hepatic vein branches subjective ratings, and calculate the hepatic portal vein trunk(MPV), left(LPV), right(RPV) image signal-to-noise ratio(SNR) and contrast to noise ratio(CNR). Results: all the 14 volunteers successfully completed two hepatic portal vein imaging examinations and obtained satisfactory images. The results of two examinations on the 14 volunteers showed that the subjective scores of the display of hepatic portal vein and hepatic portal vein branches in the images, SNR of hepatic portal vein MPV, LPV and RPV images and CNR were P > 0.05 compared with that of CNR. Conclusion: it is feasible to repeat 3.0t MRI NATIVE TrueFISP sequence in hepatic portal vein imaging.
作者 白男男 刘海荣 冯艳 董景敏 张贝贝 张林 Bai nannan;liu hairong;feng yan;dong jingmin;zhang beibei;zhang lin(Department of radiology,binzhou medical college affiliated hospital,binzhou,shandong,256603;Department of ultrasound,binzhou medical college affiliated hospital,binzhou 256603,China)
出处 《当代医药论丛》 2018年第24期15-17,共3页
关键词 肝门静脉 磁共振血管成像检查 3.0 T MRI NATIVE TrueFISP序列 hepatic portal vein Magnetic resonance angiography 3.0t MRI NATIVE TrueFISP sequence
  • 相关文献

参考文献4

二级参考文献49

  • 1Danias PG, McConnel MV, Khasgiwala VC, et al. Prospective navigator correction of image position for coronary MR angiogra- phy[J]. Radiology, 1997, 203(3) : 733-736. 被引量:1
  • 2Wilman AH, Riederer SJ, King BF. Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with ellipti- cal centric view order :application to the renal arteries[J]. Radi- ology, 1997, 205(1) : 137-146. 被引量:1
  • 3Glockner JF, Vrtiska TJ. Renal MR and CT angiography: current concepts [ J ]. Abdom Imaging, 2007, 32 ( 3 ) : 407-420. 被引量:1
  • 4赵欣智.时间-空间双重标记翻转恢复成像技术在肾动脉成像的临床研究[M].中国医科大学(影像医学与医学),2012. 被引量:1
  • 5Utsunomiya D, Miyazaki M, Nomistu Y, et al. Clinical role of non-contrast magnetic resonance angiography for evaluation of re- nal artery stenosis[J]. Circ J, 2008, 72(10) : 1627-1630. 被引量:1
  • 6Utsunomiya D, Miyazaki M, Nomitsu Y, et al. Clinical role of non- contrast magnetic resonance angiography for evaluation of renal artery stenosis [ J]. Circulation journal:official journal of the Japanese Cir- culation Society ,2008,72 : 1627-1630. 被引量:1
  • 7Parienty I, Rostoker G, Jouniaux F,et al. Renal artery stenosis eval- uation in chronic kidney disease patients: nonenhanced time-spatial labeling inversion-pulse three-dimensional MR angiography with reg- ulated breathing versus DSA[ J]. Radiology,2011,259:592-601. 被引量:1
  • 8Shonai T, Takahashi T, Ikeguchi H, et al. Improved arterial visibility using STIR fat suppression in non-contrast-enhanced Time Spatial Labeling Pulse (Time-SLIP) renal MRA [ J ]. J Magn Reson Ima- ging, 2009,29 : 1471-1477. 被引量:1
  • 9Young N, Chi KK, Ajaka J, et al. Complications with outpatient an- giography and interventional procedures [ J ]. Cardiovascular and in- terventional radiology, 2002,25 : 123-126. 被引量:1
  • 10Argalia G, Cacciamani L, Fazi R, et al. Contrast-enhanced sonogra- phy in the diagnosis of renal artery stenosis: comparison with MR- angiography[ J]. La Radiologia medica,2004,107:208-217. 被引量:1

共引文献8

同被引文献11

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部