摘要
采用理论计算和有限元实体模型的方法,对HL-2M装置低温冷凝泵及与其相连接的真空穿透结构进行了温度分布和液氦管热负荷分析。结果显示,低温冷凝泵中液氦管的热稳态热负荷为5.45W,粒子沉积的热负荷为75.68W,真空穿透部分的热负荷为5.04W。所得结果为后续的热应力分析、低温泵流速控制和低温系统的设计提供了参考。
Using the method of theoretical calculation and finite element model in ANSYS code, the studies of temperature distribution and the heat load of the liquid helium tube for the cryopump and the connecting feed through were performed. The results show that the steady heat load of the liquid helium tube is 5.45 W;particle deposition heat load is 75.68 W, and 5.04 W in the feed through. These results could be the reference for thermal stress analysis, cryopump flow velocity control and cryo system designing later.
作者
查方正
李勇
李强
邱银
卢勇
ZHA Fang-zheng;LI Yong;LI Qiang;QIU yin;LU Yong(Southwestern Institute of Physics,Chengdu 610041)
出处
《核聚变与等离子体物理》
CAS
CSCD
北大核心
2018年第3期287-292,共6页
Nuclear Fusion and Plasma Physics
基金
国家磁约束核聚变能发展研究专项(2015GB106002)