期刊文献+

MRI快速成像技术对凶险型前置胎盘的诊断价值分析 被引量:7

The Diagnostic Value Analysis of MRI Rapid Imaging Technique for the Aggressive Placenta Preplacenta
下载PDF
导出
摘要 目的:探讨核磁共振成像(MRI)快速成像技术对凶险型前置胎盘(PP)的诊断价值分析。方法:选取2015年1月至2018年1月凶险型PP患者55例,给予二维快速稳态进动(2D-FIESTA)/单次激发快速自旋回波(SSFSE)序列MRI快速成像技术检查。结果:2D-FIESTA序列胎盘信号不均匀、胎盘内条状低信号影显示率明显低于SSFSE序列,2D-FIESTA序列子宫结合带中断、胎盘与周围结构区分显示率明显高于SSFSE序列,差异有统计学意义(P<0.05);在诊断粘连性、植入性PP符合率中,二者联合时分别为96.15%、95.65%,二者联合时明显高于2D-FIESTA序列,2D-FIESTA序列明显高于SSFSE序列,差异有统计学意义(P<0.05),三种方法诊断穿透性PP符合率均为100.00%,差异无统计学意义(P>0.05)。结论:MRI快速成像技术中,SSFSE、2D-FIESTA序列均对凶险型PP胎盘植入具有良好的诊断价值,二者联合时可提高诊断价值。 Objective:To discuss the diagnostic value analysis of magnetic resonance imaging (MRI)rapid imaging technique for the aggressive placenta preplacenta (PP).Methods:55patients with aggressive PP were selected from January 2015to January 2018,they were given 2-d rapid steady-state precession (2D-FIESTA),single -induced quick-spin echo (SSFSE)sequence MRI rapid imaging technique detection.Results:The placenta signal uneven,placenta low signal display rate of 2D-FIESTA sequence were significantly lower than those of the SSFSE sequence,the uterine junction interrupted,distinguish of placenta and surrounding structure display rate of 2D-FIESTA sequence were significantly higher than those of the SSFSE sequence,the difference was statistically significant (P<0.05).In the diagnosis of adhesion,implant PP compliance,the combination of two were significantly higher than those of the 2D-FIESTA sequence,the 2D-FIESTA sequence were significantly higher than those of the SSFSE sequence,the difference was statistically significant (P<0.05),the diagnosis of penetrative PP compliance of the three methods were 100.00%,the difference was no statistically significant (P>0.05).Conclusion:In MRI rapid imaging technique,the SSFSE,2D-FIESTA sequence have good diagnostic value for the implantation placenta of aggressive PP,the combination of two can improve the diagnostic value.
作者 张婧婧 ZHANG Jing-jing(Northwest Women's and Children's Hospital,Xi'an 710061,Shaanxi Province,P.R.C.)
出处 《中国数字医学》 2018年第12期31-33,共3页 China Digital Medicine
关键词 磁共振成像 快速成像技术 凶险型 前置胎盘 诊断 magnetic resonance imaging rapid imaging technique aggressive placenta preplacenta diagnostic
  • 相关文献

参考文献2

二级参考文献23

  • 1Hsu Y R,Kung F T,Roan C J,et al. E-mergency peripartum hys- terectomy due to placenta previa/accrete 10 years experience[J].Taiwan Residents J Obstet Gynecol, 2004,15(4) : 206- 210. 被引量:1
  • 2Crum C P, Nucci M R, Lee K R. Diagnostic gynecologic and ob- stetric pathology [ M]. Netherlands: Elseviver Medicine, 2005: 1114-1115. 被引量:1
  • 3Chattopadhyay S K, Kharif H, Sherbeeni M M. Placenta praevia and accrete after previous caesarean section[J]. Eur J Obstet Gy- necol Reprod Biol, 1993,52(3) : 151- 156. 被引量:1
  • 4Masselli G,Brunelli R, Casciani E, et al. Magnetic resonance ima ging in the evaluation of placental adhesive disorders: correlation with color Doppler ultrasound[J]. Eur Radiol,2008,18(6):1292-1299. 被引量:1
  • 5Guy G P,Peisner D B,Timor-Tritsch I E. Ultrasonographic eva- lution of uteroplacental blood flow patterns of abnormally loca- ted and adherent placentas[J]. Am J Ohstet Gynecol, 1990,163 (3) :723-727. 被引量:1
  • 6Chattopadhyay SK,Kharif H,Sherbeeni MM. Placenta praevia and accreta after previous caesarean section[J].European Journal of Obstetrics & Gynecology and Reproductive Biology,1993,(03):151-156. 被引量:1
  • 7Hsu YR,Kung FT,Roan CJ. E-mergency peripartum hysterectomy due to placenta previa/ accrete:10 years' experience[J].Taiwan Residents J Obstet Gynecol,2004,(04):206-210. 被引量:1
  • 8卢萍.47例前置胎盘终止妊娠的体会[J]中华实用医药杂志,2003(04):124-125. 被引量:1
  • 9乐杰.妇产科学[M]北京:人民卫生出版社,2008116-117. 被引量:1
  • 10Miller DA,ChollerJA,Gooduin TM. Clinical risk factors for placenta previa plamata aecreta[J].American Journal of Obstetrics and Gynecology,1997,(01):210-211. 被引量:1

共引文献44

同被引文献57

引证文献7

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部