GDT导致的非标低压浪涌失效分析 被引量:1

Failure Analysis on Non-Standard Low Voltage Surge Caused by GDT
下载PDF
导出
摘要 GDT是通讯设备中常用的浪涌防护器件,其浪涌动作特性直接影响防护效果。大部分标准对于浪涌测试指标都是一个固定的等级,而实际现网应用时,端口感应电压都是非标准的,即使等级低于测试标准,也会导致端口失效。该文详细分析了因GDT导致的非标低压浪涌防护失效案例,指出非标测试的必要性,对提高产品的现网使用健壮性有非常重要的意义。 Gas discharge tube(GDT)is a common surge protection device in communication equipment.Its surge action characteristics directly affect the protection level.Most of the standards have a fixed level for surge test index,but the induction voltage is uncertain in the actual application of the network.This paper analyses the failure cases of non-standard low voltage surge protection caused by GDT,and points out the necessity of non-standard testing,which is very meaningful to improve the robustness of the products in the actual application.
作者 刘婷 李燕兵 任立立 Liu Ting;Li Yan-bing;Ren Li-li(ZTE CORPORATION,Jiangsu Nanjing 210012)
出处 《电子质量》 2018年第12期39-42,共4页 Electronics Quality
关键词 气体放电管 浪涌 低压 非标测试 健壮性 Gas discharge tube(GDT) Surge Low voltage Non-standard testing Robustness