期刊文献+

注入式植入可折叠人工晶体手术的临床观察 被引量:7

Clinical observation of the implantation of foldable intraocular lens (IOL) with injector
原文传递
导出
摘要 目的 :探讨用注入式植入可折叠人工晶体手术的临床效果。方法 :对 2 0例 (2 1眼 )老年性白内障患者行超声乳化白内障摘除联合可折叠人工晶体植入手术 ,植入的人工晶体为 Canon- Staar的可折叠人工晶体。用其配套的注入器 (一次性 )植入晶体囊袋内。结果 :手术均顺利完成 ,未发生术中并发症。术后第一天矫正视力≥ 0 .5者达 71.4% ,术后 1个月矫正视力≥ 0 .5者达 10 0 %。结论 :注入式植入人工晶体可起真正小切口的作用 ,能进一步减少对眼球组织的损伤。 Objective: To investigate the clinical effects of the implantation of foldable intraocular lens (IOL) with injector. Methods: Twenty patients (21 eyes) had received phacoemulsification and then the foldable IOL Were implanted into capsule bags with the matched injector. Results: All operations were successful and no complications occurred. Visual acuity was 0.5 or better in 15 eyes (71.4%) on the first day post-operations and in all cases after one month. Conclusions: The injector is helpful for IOL implantation to obtain a real small incision and makes less injury to eyes.
出处 《中国实用眼科杂志》 CSCD 北大核心 2001年第12期909-909,共1页 Chinese Journal of Practical Ophthalmology
关键词 超声乳 人工晶体 注入式 可折叠式 Phacoemulsification, Intraocular injector
  • 相关文献

同被引文献30

  • 1沈伟锋.初学白内障超声乳化联合折叠人工晶体植入术的体会[J].实用防盲技术,2007,2(3):20-22. 被引量:3
  • 2Nielsen PJ.Prospective evaluation of surgically induced astigmatism and astigmatic keratomy effects of various self-sealing small incision.J Cataract Refract Surg,1995,21 (1):43-48. 被引量:1
  • 3Mastropasqua L,Toto L,Nubile M,et al.Clinical study of the ICU accommodating intraocular lens.J Cataract Refract Surg,2003,29(7):1307-1312. 被引量:1
  • 4Fine IH,HoffmanR,Packer M.O ptimizing refractive lens exchange wi thbimanual Inl' croincision phacoemulsification[J]. Cataract Refract Surg,2006,30(5):550-554. 被引量:1
  • 5邓承,刘荣华.白内障手术不同切口对视力和屈光力的影响[J].中华眼科杂志,1997,33(3):195-197. 被引量:64
  • 6Faschinger CW. Surface abnormalities on hydrophilic acrylic intraocular lenses implanted by an injector. J Cataract Refract Surg 2001 27:845-849. 被引量:1
  • 7Hating G, Winter M, Behrendt S. Effect of folding on the multifocal silicone intraocular lens: scanning electron microscopic study. J Cataract Refract Surg 1999 25:1505-1509. 被引量:1
  • 8Mamalis N, Incision width after phacoemulsification with foldable intraocular lens implantation, J Cataract Refract Surg 2000 26 : 237-241. 被引量:1
  • 9Kohnen T, Incision sizes with 5.5 mm total optic, 3 - piece foldable intraocular lenses. J Cataract Refract Surg 2000 26:1765--1772. 被引量:1
  • 10Oshika. T, Shiokawa. Y. Effect of folding on the optical quality of soft acrylic intraocular lenses.J Cataract RefractSurg, 1996;22(2): 1360-1364 被引量:1

引证文献7

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部