期刊文献+

云浮发电厂高压导汽短管裂纹原因分析及整改措施 被引量:1

Cause analysis and tackling of cracks on short HP steam conduits in Yunfu Power Plant
下载PDF
导出
摘要 云浮发电厂 2号机高压导汽短管多次发生裂纹。为此 ,从裂纹发生的具体部位、短管几何尺寸、材质性能、金相组织以及断口电镜等方面进行了分析。分析认为 ,裂纹属于高温疲劳裂纹 ,材质不合格是产生疲劳裂纹的主要原因 ,短管焊缝处于应力集中处是产生疲劳裂纹的次要原因。并且采取相应的整改措施。 In light of the multiple cracks that took place on the short HP steam conduits of Unit 2 in Yunfu Power Plant,an analysis is conducted in terms of the trouble spots,conduit dimensions,material properties,metallurgical structure and electronfractography. It is concluded that the cracks were heat fatigue cracks that mainly resulted from poor quality material and partially from the concentrated stress on the welded joints. Corresponding measures are then taken to tackle the problem.
出处 《广东电力》 2001年第5期56-59,共4页 Guangdong Electric Power
关键词 高压导汽管 裂纹 分析 汽轮机 N125-135/535/535型 发电厂 steam conduit crack cause analysis
  • 相关文献

参考文献1

  • 1佚名.云浮发电厂2号机高压导汽短管产生裂纹原因分析报告[M].沈阳:中国科学院金属研究所,2000.. 被引量:1

同被引文献8

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...