乙烯装置蒸汽系统的优化 被引量:6

OPTIMAL DISPATCH FOR STEAM SYSTEM OF ETHYLENE PLANT
下载PDF
导出
摘要 针对抚顺石油化工公司乙烯装置扩容改造后 ,蒸汽系统失去操作弹性 ,工况无法进行调整 ,造成能耗和生产成本偏高 ,运行可靠性下降等问题 ,利用有效的优化调度方法 ,建立了蒸汽系统热平衡优化计算的数学模型 ,通过优化计算分析蒸汽系统变工况的性能和诊断系统能耗高的症结所在 ,提出节能改造方案 ,并对改造后的蒸汽系统实施优化调度和管理。实施结果表明 :蒸汽系统恢复了操作弹性 ,可节省高压蒸汽 8t/h ,每年节约经费 10 0 0万元 ,实现了节能减耗、提效的目的。 Some problems, such as loss of operation elasticity of the steam system, higher energy consumption and production cost, and descent of running stability, were emerged after the capacity expansion of the ethylene plant in Fushun Petrochemical Company. An effective optimization and dispatch method was introduced to build a mathematical model for heat balance calculation of the steam system. The performance of the steam system under variable conditions was calculated and analyzed, and the crux of high energy consumption was diagnosed. An energy conservation scheme was proposed and optimal dispatch and management of the reformed steam system was realized. After the scheme put into effect, the operation elasticity was recovered and 8t/h high pressure steam was saved.
出处 《石油炼制与化工》 CAS CSCD 北大核心 2001年第10期49-50,共2页 Petroleum Processing and Petrochemicals
基金 国家"攀登计划B"(85- 3 5 )
关键词 乙烯装置 蒸汽系统 能耗 优化 数学模型 节能 ethylene unit steam energy consumption optimization mathematical models energy conservation
  • 相关文献

参考文献3

  • 1[1]Clary A T. Open Loop Optimization of a Complex Steam Cogeneration System, Power Division (Publication) PWR Proceedings of 1996 International Joint Power Generation Conference. Part2 (of 2) Vol 30 1996Houston, US 被引量:1
  • 2沈幼庭,何锦英编著..热力系统及设备最优化[M].北京:机械工业出版社,1985:405.
  • 3何建坤,江道琪,陈松华..实用线性规划及计算机程序[M].北京:清华大学出版社,1985:251.

同被引文献88

引证文献6

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部