摘要
通过对妈湾 1#机组的实验分析 ,总结出在不同负荷下 30 0MW机组的经济解决 30 0MW机组作为调峰机组的经济性问题。试验证明定 -滑 -定具有较高的经济性和安全性。
Through experimental analysis of Mawan No.1 generator set,authors conclude that under various loads the difficult problem of economical operation of 300?MW set has been solved that to put the 300?MW set as a peak modulation set in operation is an economical way of power plant operation. Experiments prove that generator operating mode of fixed slip fixed is more thrifty and safety.
出处
《东北电力学院学报》
2001年第3期72-74,共3页
Journal of Northeast China Institute of Electric Power Engineering