期刊文献+

80kA预焙阳极电解槽电压平衡测试与分析 被引量:2

Test and Analyses for Voltage Balance of 80kA Pre-baking Anode Electrobath
下载PDF
导出
摘要 对山铝电解铝厂的 80 k A预焙阳极电解槽的阳极压降、阴极压降、极间电压及母线压降进行测试 ,并根据测试数据进行电压平衡计算 ,认为电压分配比较合理 ,阳极压降偏高。为降低电解槽电压提供了理论依据。 The voltage drops of anode,cathode,the voltage between two poles and the voltage drops of generatrix of 80kA pre baking anode electrobath were tested in Aluminium Electrolysing Works of Shandong Aluminium Industry Co.,Ltd.The calculation of voltage balance was carried out according to the test data.The voltage assigning was recognized suitable,voltage drop of anode was on the high side,supplying the theoretical base for reducing the voltage of electrobath.
出处 《山东冶金》 CAS 2001年第3期50-51,共2页 Shandong Metallurgy
关键词 铝电解槽 电压平衡 测试 预焙槽 aluminium electrobath voltage balance test