摘要
以实测数据为基准,应用对称分量法原理,考虑了配电网三相不平衡问题,为综合测试仪测试数据进行配电网线损计算提供了新算法,与传统的“按容量分配负荷法”相比,有更严格的理论依据和更高的精度。算例验证了该方法的可行性。
A new algorithm for calculation line losses on distribution network based on data measured by the synthetic instrument is proposed by taking the measured data as referece, applying symmetrical component theory and considering three phase unbalance on distribution network. In compared with the traditional method of load distributed by capacity, the new algorithm supported by practical calculation presents strict theoretical basis and higher accuracy.
出处
《中国电力》
EI
CSCD
北大核心
1998年第9期31-33,共3页
Electric Power
关键词
配电网
线损计算
综合测试数据
对称分量法
distribution line losses synthetic measuring instrument symmetrical component method