摘要
汕头发电厂一台柴油发电机组的排气测温系统出现较大的误差,通过对 测温系统热量损失的计算与分析,找出了引起热电偶测温误差的主要原因,并用 红外辐射测温仪对热电偶测温误差进行了检验。在此基础上提出了修正方法。
There is a larger error in the temperature measurement system of one diesel generator's exhaust sys- tem.The main reasons of causing thermocouple temperature measurement's error were obtained by heat loss calculating and analyzing, and the inspection of thermocouple temperature measurement's error was done by a infrared radiation thermometer. On the basis of this, the, modificatory methods were proposed.
出处
《节能》
2001年第7期42-44,共3页
Energy Conservation