电厂自动启停技术(APS)是我国火电厂顺序控制系统的最新发展。本文以国华三河电厂为实例,简要介绍APS的具体内容,并结合实际应用经验,提出完善优化APS 的几点看法。
The automatic start-up and shutdown technology of thermal power plant(APS) is the latest development of sequence control system of thermal power plant in China. This paper with Guohua Sanhe Thermal Power Plant as an example briefly introduces the concrete contents of APS and combining with the actual application experiences puts forward the proposals to perfect and optimize APS.