一种用于天文台选址的气象参数和大气湍流测量系统 被引量:7

A Meteorological Parameter and Atmospheric Turbulence Measurement System for Locating Astronomical Observatory
下载PDF
导出
摘要 本文提出一种用VFC(电压-频率变换器)进行模数转换的气象参数和温度脉动测量系统.系统安装在云南天文台高美古观测站一27m高铁塔上,包括三层金属丝温度脉动传感器和温度、湿度、气压、风速、风向传感器.用计算机选通多路开关,8253计数器对脉冲信号计数,实时测量和显示数据.成本低,能保证长距离数据采集的精度. A meteorological parameter and atmospheric turbulence measurement system was described in this paper. A/D conversion was done by VFC (Voltage Frequency Changer). The system has been implemented at a 27 m tower in Gaomeigu Yunnan Astronomical Observatory, that includes three levels fast-response temperature sensors and two slow-response temperature sensors, a humidity sensor, a pressure sensor, a propeller-vane anemometer, Computer selects input channels and pulse signal is counted by 5253 counter, so the system cost is low and the measuring precision of long distance sampling signal can be ensured.
出处 《量子电子学报》 CAS CSCD 北大核心 2001年第2期184-187,共4页 Chinese Journal of Quantum Electronics
关键词 大气湍流测量系统 气象参数 天文台选址 VFC frequency count turbulence measurement system
  • 相关文献

参考文献2

二级参考文献7

  • 1杨广才.大气探测文集[M].北京:气象出版社,1990.. 被引量:1
  • 2黄炳勋.Gzz-7型探空仪温度远见的辐射误差及滞后误差[M].北京:气象出版社,1985,1.. 被引量:1
  • 3近藤纯正(日) 石安英(译).大气边界层的科学[M].北京:中国科学技术出版社,1986.79. 被引量:2
  • 4杨广才,大气探测文集,1990年 被引量:1
  • 5李英干,湿度测量,1990年,112页 被引量:1
  • 6石安英(译),大气边界展的科学,1986年,79页 被引量:1
  • 7黄炳勋,Gzz-7型探空仪温度远见的辐射误差及滞后误差,1985年 被引量:1