摘要
根据建筑物防雷理论和规范要求,结合广州国际金融中心(广州西塔)工程实例,详细介绍超高层建筑防雷设计方法,包括参考雷击风险评估报告确定防雷等级,以及防直击雷、防侧击雷、防雷击电磁脉冲的措施等,并提示超高层建筑防雷设计注意事项。近几年雷暴的考验,证明广州西塔防雷设计先进、合理、可靠。
Design methods of protection against lightning for super high-rise buildings are introduced in detail according to protection against lightning theories and specification clause for buildings in combination with practical engineering project of Guangzhou International Finance Center ( Guangzhou West Tower). Protection against lightning class determined according to a lightning risk assessment report, and measures for protection against direct lightning, side lightning and protection against lightning electromagnetic impulse are also proposed, and matters in design of protection against lightning for super high-rise buildings are prompted. Proved by thunderstorms over the years, the design of protection against lightning for Guangzhou West Tower is advanced, reasonable and reliable.
出处
《建筑电气》
2014年第6期18-22,共5页
Building Electricity
关键词
超高层建筑
雷击风险评估
接闪器
引下线
均压环
法拉弟笼
防雷等电位连接
防雷击电磁脉冲
super high-rise building
lightning risk assessment
air-termination system
down-conductor system
grading ring
Faraday cage
lightning equipotential bonding
protection against lightning electromagnetic impulse