期刊文献+

CBCT头颅侧位片在头影测量中可重复性的研究 被引量:9

A study on repeatability of 3D cephalometric from CBCT and cephalogram
原文传递
导出
摘要 目的:比较锥形束CT(CBCT)三维头影测量与CBCT转化头颅侧位片(Cephalogram from CBCT,CCB)及数字化X线头颅侧位片(Digital Cephalogram,DC)头影测量的可重复性和可靠性。方法:对一名成年人进行CBCT扫描并拍摄数字化X线头颅侧位片。使用Invivo Dental 5.0软件对CBCT图像进行三维测量;CCB和DC采用Winceph 8.0软件进行二维头影测量。选择常用测量项目15项,同一操作者对3种图像测量15次。对CBCT,CCB及DC测量可重复性进行统计学分析,三者间可重复性差异采用方差分析。结果:CCB测量可重复性优于CBCT和DC(P<0.05)。15个测量项目中CCB有8个测量项目精确度明显高于CBCT和DC。结论:CBCT三维影像能真实反映颅颌面空间结构,弥补二维图像失真,解剖结构重叠的不足。CCB测量可重复性优于CBCT三维测量和传统X线头颅侧位片二维测量,在三维测量系统完善前,CCB是头影测量由二维向三维过度的重要测量方法。 Objective:To compare the repeatability and reliability of linear and angular measurements made on three-dimensional(3D) cone beam CT(CBCT) and two-dimensional(2D) cephalogram from CBCT(CCB),digital cephalogram (DC). Method:One patient was scanned with CBCT and then X-reyed digital cephalogram.CBCT 3D image was traced us-ing Invivo Dental 5.0 software. Winceph 8.0 software was used to identify landmarks on CCB and DC.15 cephalometric mea-surements were registered on all images 15 times by the same operator.Statistical analysis to test the repeatability of CBCT, CCB and DC.Analysis of variance(ANOVA) was used to compare the three methods. Result:CCB measurement repeatability is better than that of CBCT and DC (P〈0.05). Of 8 measurements accuracy obviously geater than that of CBCT and DC. Conclusion:CBCT three-dimensional images reflect cranial and maxillofacial structure, make up the conventional cephalo-metric distortion and overlap. CCB repeatability is better than that of CBCT three-dimensional measurement and X-ray two-dimensional measurement.In front of the 3 D measurement system is clear and perfect,CCB was a important method from 2 D to 3D measurement.
出处 《临床口腔医学杂志》 2014年第6期371-374,共4页 Journal of Clinical Stomatology
基金 辽宁省自然科学基金资助(201202235)
关键词 锥形束CT 三维头影测量 可重复性 cone-beam computed tomography 3D analysis: repeatability
  • 相关文献

参考文献12

  • 1Yitschaky O,Redlich M,Abed,et al. Comparison of common hard tissue cephalometric measurements between computed tomography 3D reconstruction and conventional 2D cephalometric images [J]. Angle Orthod, 2011, 81 (1) : 13-18. 被引量:1
  • 2Adams GL, Gansky SA, Miller AJ, et al. Comparison between tradi- tional 2-dimensional cephalometry and a 3-dimensional approach on human dry skulls[J]. Am J Orthod Dentofacial Orthop, 2004, 126 (5) : 397-409. 被引量:1
  • 3Scarfe WC,Farman AG, Sukovic P. Clinical applications of cone beam computed tomography in dental practice [J]. Journal of the Canadian Dental Association, 2006, 72 (1) : 75-80. 被引量:1
  • 4马绪臣编著..口腔颌面锥形束CT的临床应用[M].北京:人民卫生出版社,2011:168.
  • 5Harrel WE, Hatcher DC, Bolt RL. In search of anatomic truth:3-di- mensional modeling and the future of orthodontics [J]. Am J Orthod Dentofacial Orthop, 2003, 122 (3) : 325-330. 被引量:1
  • 6Farman AG, Scarfe WC. Development of imaging selection criteria and procedures should precede cephalometric assessment with cone beam computed tomography [J]. Am J Orthod Dentofacial Orthop, 2006, 130(2) : 257-265. 被引量:1
  • 7Van Vlijmen OJ,Berge SJ,Swennen GR,et al. Comparison of cephalometric radiographs obtained from cone-beam computed to- mography scans and conventional radiographs [J]. Int J Oral Maxil- lofac Surg, 2009, 67 (1) : 92-97. 被引量:1
  • 8Ludlow JB,Gubler M,Cevidanes L, et al. Precision of cephalometric landmark identification:cone-beam computed tomography vs con- ventional cephalometric views[J]. Am J Orthod Dentofacial Orthop, 2009,136(3) : 312-313. 被引量:1
  • 9刘怡,赵健慧,丁云,许天民.锥形束CT转化头颅侧位片定点精确性的研究[J].中华口腔正畸学杂志,2010,17(2):61-65. 被引量:31
  • 10Yoon YJ, Kim KS, Hwang M S, et al. Effect of head rotation on late- ral cephalometric radiographs [J]. Angle Orthod, 2001,71 (5) : 396- 403. 被引量:1

二级参考文献11

  • 1李晓智,温兴涛,周建,王萍.X线片质量对手工定点可重复性的影响[J].华西口腔医学杂志,2004,22(4):342-343. 被引量:5
  • 2Baumrind S,Frantz RC.The reliability of head film measurements.1.Landmark identification.Am J Orthod,1971,60:111-127. 被引量:1
  • 3Mah J,Hatcher DC.Craniofacial imaging in orthodontics.In:Graber TM,Vanarsdall RL,Vig KWL,editors.Orthodontics:current priniples and techniques.St Louis:Elsevier,2005,71-100. 被引量:1
  • 4Yoon YJ,Kim KS,Hwang MS,et al.Effect of head rotation on lateral cephalometric radiographs.Angle Orthod,2001,71:396-403. 被引量:1
  • 5Cho HJ.A three-dimensional cephalometric analysis.J Clin Orthd,2009,43,235-252. 被引量:1
  • 6Ludlow JB,Gubler M,Cevidanes L,et al.Precision of cephalometric landmark identification:cone-beam computed tomography vs conventional cephalometric views.Am J Orthod Dentofacial Orthop,2009,136:312. 被引量:1
  • 7Chien PC,Parks ET,Eraso F,et al.Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo.Dentomaxillofac Radiol,2009,38:262-273. 被引量:1
  • 8Waitzman AA,Posnick JC,Armstrong DC,et al.Craniofacial skeletal measurements based on computed tomography:Part Ⅰ.Accuracy and reproducibility.Cleft Palate Craniofac J,1992,29:112-117. 被引量:1
  • 9Waitzman AA,Posnick JC,Armstrong DC.et al.Craniofacial skeletal measurements based on computed tomography:Part Ⅱ.Normal values and growth trends.Cleft Palate Craniofac J,1992,29:118-128. 被引量:1
  • 10Van Vlijmen OJ,Maal TJ,Bergé SJ,et al.A comparison between two-dimensional and three-dimensional cephalometry on frontal radiographs and on cone beam computed tomography scans of human skulls.Eur J Oral Sci,2009,117:300-305. 被引量:1

共引文献30

同被引文献91

引证文献9

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部