采用ECCS的计算模型和单元分析的计算模式 ,利用计算机程序 ,经过大量统计分析与计算 ,得到了钢管混凝土轴压构件抗火承载力的回归计算公式 ,并与国内外的结果对比 ,吻合较好 。
A large amount of statistic calculation on the squash load of centrally loaded concrete filled steel tubular columns exposed to fire has been carried out through using the computer program, and the regression formulas are established. From the comparisons of results respectively obtained by the formulas and experiments, it is concluded that the formulas are applicable with reasonable accuracy for fire resistant design of concrete filled steel tubular columns.
出处
《建筑结构》
CSCD
北大核心
2001年第1期60-62,59,共4页
Building Structure
关键词
钢管混凝土
抗火承载力
轴压构件
计算
concrete filled steel tubular columns
centrally loaded
fire resistant
load bearing capacity