摘要
本文通过对三亚南山导航台NEXTFIELD类型的DVOR4000设备安装调试过程及相关问题的分析,总结出此类设备安装调试的步骤和区别于以往DVOR4000安装调试设备的方法。并针对此设备校飞中出现的问题进行分析和研究解决的方法,最终解决了该设备校飞中存在的问题。为今后该类型设备的安装调试和故障排除提供参考依据。
This article through to Sanya Nanshan beacon Nextfield types of DVOR4000 equipment installation commissioning process and related problem analysis,summed up such equipment installation and debugging steps and different from previous DVOR4000 installation debugging equipment method. And in the light of the failures troubleshooting and analysis,finally solved the problems existing in the flight check. Providing experience and ways in installation and debugging and troubleshooting for maintenance personnel.
出处
《科技资讯》
2014年第9期45-46,共2页
Science & Technology Information