摘要
本文测量了有防护和无防护手术间外X射线的辐射剂量,通过分析测量数据,说明了C形臂X射线机在无放射防护手术间中使用将对周围工作人员产生辐射危害,探讨手术间在无防护条件下电离辐射防护的解决方案。
The X-ray radiation doses in protected and non-protected operation room were measured. By analyzing the measurement data, it is proved that C-arm X-ray machine, without protection measures, will produce radiation hazard to the staff around the operation room. The solutions to the prevention of ionizing radiation in non-protected operation room are discussed in this paper.
出处
《中国医疗设备》
2014年第6期14-15,21,共3页
China Medical Devices
基金
军事医学计量专项(2011-JL3-013)
关键词
C形臂X射线机
放射防护
手术间
C-arm X-ray machine
radiation protection
operation room