深业物流中心超高层结构选型与超限分析 被引量:3

Structural system selection and out-of-code analysis of super-tall Shenye Logistics Center Tower
原文传递
导出
摘要 深业物流中心塔楼建筑高度316.16m,采用框架-核心筒结构体系。比较了钢筋混凝土楼盖体系与钢结构楼盖体系对结构工作性能及经济性的影响;探讨了为满足剪重比要求而设置加强层的合理性。针对超限高层建筑进行了结构弹性、弹塑性分析和针对一些不规则项的专项分析。分析结果表明,选取的结构体系是合理的,且结构性能满足抗震设防性能目标的要求。 Shenye Logistics Center Tower building with the height of 316. 16 meters adopts frame-core wall structural system. The influence of concrete floor system and steel floor system on structural performance and economic efficiency was compared. The rationality of the installation of strengthening layers to satisfy the requirement of shear-weight ratio was discussed. Elastic analysis,elasto-plastic analysis and specializedanalysis targeting at some irregular specifications were carried out on this out-of-code super-tall building. Analysis results conclude that the selected structural system is suitable and its structural performance can meet the requirements of performance-based seismic fortification targets.
出处 《建筑结构》 CSCD 北大核心 2014年第10期25-30,24,共7页 Building Structure
关键词 加强层 剪重比 抗震性能 超高层结构选型 strengthening layer shear-weight ratio seismic performance structural system selection of super-tall building
  • 相关文献

参考文献2

二级参考文献7

  • 1.GB50017-2003钢结构设计规范[S].北京:中国计划出版社,2003.. 被引量:670
  • 2GB50011-2001.建筑抗震设计规范[S].北京:中国建筑工业出版社.2008:19-24. 被引量:82
  • 3GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010. 被引量:947
  • 4JGJ99-98高层民用建筑钢结构技术规程[S].北京:中国建筑工业出版社,1998. 被引量:78
  • 5American Society of Civil Engineers. Prestand and commentary guidelines for the seismic rehabilitation of buildings [ R]. FEMA-356, Washington D. C. : Federal Emergency Management Agency, 2000. 被引量:1
  • 6孙广俊,李爱群.关于结构振型参与系数和振型贡献的分析[J].防震减灾工程学报,2009,29(5):485-490. 被引量:1
  • 7王兴法,林超伟,许波,李开伦,雷霆,熊亮.贵阳201大厦结构体系研究[J].建筑结构,2012,42(3):10-14. 被引量:12

共引文献26

同被引文献10

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部