摘要
通过对百色双套自动气象站遇到历史罕见的强雷暴袭击出现故障维修,摸索出了检修双套新型自动站的通信、电源供应、主机HY3000、接口RS232、分采仪器等模块的方法,供同行借鉴。
Based on malfunction maintenance for automatic weather stations in Baise history of rare strong thunderstorm attacks, the method for overhaul double set of new type automatic station communication, power supply, the host HY3000, interface RS232, points and mining equipment were explored to provide reference for the colleague.
出处
《气象研究与应用》
2014年第1期97-98,共2页
Journal of Meteorological Research and Application
关键词
百色双套自动气象站
雷击故障
维修思路与过程
double set of automatic weather station
lighting malfunction