期刊文献+

电流互感器潜伏性故障的原因分析及处理措施

Cause analysis and treatment measures of potential fault in current transformer
下载PDF
导出
摘要 针对哈尔滨电业局近年来电流互感器潜伏性故障频发的问题,阐述了油中溶解气体色谱分析诊断故障的方法,分析了形成电流互感器故障的原因,提出了相应的处理措施。实践证明,利用油中溶解气体色谱分析技术,可以及时准确地诊断出电流互感器的潜伏性故障及其位置,并有利于技术人员对其分析及处理。 Aiming at the frequent potential faults taking place in current transformer, this paper expounds the fault diagnosis with dissolved gas chromatographic analysis, analyzes the causes for faults, and proposes relevant treat- ment measures. The practice proves that it is able to diagnose potential fault and its position timely and accurately by dissolved gas chromatographic analysis, which is beneficial for technical staff to analyze and treat the fault.
出处 《黑龙江电力》 CAS 2014年第2期185-188,共4页 Heilongjiang Electric Power
关键词 电流互感器 潜伏性故障 溶解气体 色谱分析 current transformer potential fault dissolved gas chromatographic analysis
  • 相关文献

参考文献5

  • 1朱德恒,严璋.高电压绝缘[M].北京:清华大学出版社,1982. 被引量:3
  • 2操敦奎编著..变压器油色谱分析与故障诊断[M].北京:中国电力出版社,2010:216.
  • 3汪红梅.电力用油(气)[M].北京:化学工业出版社,2008. 被引量:15
  • 4曹继丰.高压直流输电现场实用技术问答[M].北京:中国电力出版社,2008. 被引量:3
  • 5朱德恒,严璋.高电压绝缘技术[M].北京:中国电力出版社,2007. 被引量:1