期刊文献+

无速度传感器笼型感应电机风力发电控制 被引量:3

Control of Speed Sensor-Less Squirrel-Cage Induction Generator Wind Power System
下载PDF
导出
摘要 研究了基于无速度传感器笼型感应电机全功率变流风力发电系统的控制策略。根据笼型感应电机的特性,机侧变换器采用基于模型参考自适应算法的无速度传感器直接转矩控制,网侧变换器采用电压电流双闭环控制策略。仿真结果表明:成功实现了转速调节及笼型感应电机风力发电系统有功和无功电流的独立控制,验证了所提方案的可行性。 A control strategy using speed sensor-less squirrel-cage induction generator (SCIG) full power converter wind power system was studied. According to the SCIG's characteristics and the model reference adaptive control theory, direct torque control strategy based on speed sensor-less was adopted for the generator side converter. And the voltage oriented control and current dual close-loop control strategy were used for the grid side converter. The simulation results show that the control strategy can realize generator rotational speed regulation, and the active and reactive power control are achieved independently. The feasibility of the method was validated.
出处 《电机与控制应用》 北大核心 2014年第3期47-51,共5页 Electric machines & control application
基金 上海市教育委员会重点学科建设目资助(J51301) 上海市教委自然科学基金(07ZZ146)
关键词 笼型感应电机 直接转矩控制 电网电压定向 无速度传感器 风力发电 squirrel-cage induction generator direct torque control grid voltage orientation wind power generation speed sensor-less
  • 相关文献

参考文献9

二级参考文献32

  • 1李建林,赵栋利,李亚西,许洪华.适合于变速恒频双馈感应发电机的Crowbar对比分析[J].可再生能源,2006,24(5):57-60. 被引量:49
  • 2Xiang Dawei, Li Ran. Control of a doubly fed induction generator in a wind turbine during grid fault ride-through[J]. IEEE Transaction on Energy Conversion, 2006, 21(3): 652-662. 被引量:1
  • 3Manoj R Rathi, Ned Mohan. A novel robust low voltage and fault ride through for wind turbine application operating in weak grids[C]. Proceedings of the 31st Annual Conference of IEEE on Industrial Electronics Society, 2005: 2481-2486. 被引量:1
  • 4Petersson A, Lundberg S, Thiringer T. A DFIG wind turbine ride-through system, influence on the energy production[J]. Wind Energy, 2005, 8(3): 251-263. 被引量:1
  • 5Janos Rajda, Anthony William Galbraith, Colin David Schauder. Device, system and method for providing a low-voltage fault ride-through for a wind generator farm: United States, US 2006/0267560 A1 [P]. 2006. 被引量:1
  • 6Zhan C, Barker C D. Fault ride-through capability investigation of a doubly-fed induction generator with an additional series-connected voltage source converter[C]. Proceedings of the 8th IEE International Conference on AC and DC Power Transmission, 2006 79-84. 被引量:1
  • 7Flannery P S, Venkataramanan G. Evaluation of voltage sag ride-through of a doubly fed inductiongenerator wind turbine with series grid sideconverter[C]. IEEE Power Electronics Specialists Conference, 2007: 1839-1845. 被引量:1
  • 8Erlich I, Wrede H, Feltes C. Dynamic behavior of DFIG-based wind turbine during grid faults[C].Power Conversion Conference, Nagoya, Japan, 2007: 1195-1200. 被引量:1
  • 9Abbey C, Joos G. Effect of low voltage ride through (LVRT) characteristic on voltage stability[C]. IEEE Power Engineering Society General Meeting, 2005, 2: 1901-1907. 被引量:1
  • 10Miguel Rodriguez, Gonzalo Abad, Izaskun Sarasola, et al. Crowbar control algorithms for doubly fed induction generator during voltage dips[C]. 2005 European Conference on Power Electronics and Applications, 2005: 1-10. 被引量:1

共引文献232

同被引文献16

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部