摘要 对多阵元合成孔径聚焦超声成像进行了全面的研究.根据声场的辐射理论推导了多阵元孔径的声压分布,并分别对单阵元、多阵元聚焦和多阵元非聚焦的声场和缺陷响应进行了仿真,发现多阵元非聚焦的声场更适合于合成孔径聚焦超声成像,并根据这个原则进行了成像实验,结果表明在远场情况下,多阵元合成孔径聚焦超声成像可以获得比单阵元合成孔径聚焦成像更高的成像质量和分辨力. The principle of multi-element synthetic aperture focusing imaging was studied. Acoustic field characteristics of multi-element aperture are derived employing the acoustics radiation theory. And simula- tion of one-element, multi-element focusing and multi-element un-focusing acoustic field and defect was re- spectively carried out. It is shown that better results can be achieved in synthetic aperture imaging in multi- element un-focusing acoustic field. Experiments were implemented based on this conclusion. The results show that better resolution and image quality can be achieved through multi-element imaging than single el- ement in the far field.
作者 杜英华 祁欣
出处 《纳米技术与精密工程》 CAS CSCD 2014年第3期162-166,共5页 Nanotechnology and Precision Engineering
关键词 多阵元 合成孔径 超声成像 muhi-element synthetic aperture ultrasonic imaging
  • 相关文献

参考文献10

  • 1Flaherty J J, Erikson K R, Van Lun M. Synthetic Aperture Ultrasonic Imaging Systems: USA, 3548642[ P]. 1970-12- 22. 被引量:1
  • 2Chang J H, Park J W, Song T-K. A new synthetic aperture focusing method using nonspherical wave fronts [ C ]//IEEE Ultrasonics Symposium. Atlanta, GA, 2001, 2: 1525-1528. 被引量:1
  • 3Tong Jian-Hua, Liao Shu-Tao, Lin Chao-Ching. A new elas- tic-wave-based imaging method for scanning the defects in- side the structure [ J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2007, 54 ( 1 ) : 128- 137. 被引量:1
  • 4Pollakowski M, Ermert H. Chirp signal matching and signal power optimization in pulse echo mode ultrasonic nondestruc- tive testing[ J]. IEEE Transactions on Ultrasonics, Ferroe-lectrics, and Frequency Control, 1994, 41 (5) : 655-659. 被引量:1
  • 5Gran F, Jensen J A. Designing waveforms for temporal enco- ding using a frequency sampling method[ J]. IEEE Transac- tions on Ultrasonics, Ferroelectrics, and Frequency Control, 2007, 54(10): 2070-2081. 被引量:1
  • 6O' Donnell M, Thomas L J. Efficient synthetic aperture ima- ging from a circular aperture with possible application to catheter-based imaging[ J]. 1EEE Transactions on Ultrason- ics, Ferroelectrics, and Frequency Control, 1992, 39 ( 3 ) : 366-380. 被引量:1
  • 7Pignone E, Stanchi P. Enhancement in defect detection, lo- cation and sizing in hollow axis rotors, an innovative method to improve ultrasonic image quality: The multi-SAFT & multi-probe approach [ C ]//International Workshop on Ima- ging Systems and Techniques. Minori, Italy, 2006: 163- 168. 被引量:1
  • 8Ylitalo J, Ermert H. Evaluation of a synthetic aperture ultra- sonic imaging method using a commercial B-scanner[ C ]// Proceedings of the Annual International Conference-IEEE En- gineering in Medicine and Biology Society. 1993, 1: 224- 225. 被引量:1
  • 9Liou Ren-Jean, Kao Kuang-Chien, Yeh Chin-Yung, et al. Flaw detection and sizing of ultrasonic images using wavelet transform and SAFT[ C ]//Proceedings of 2004 International Symposium on Intelligent Signal Processing and Communica- tion Systems. 2004 : 106-110. 被引量:1
  • 10Mustafa K, Li Pai-Chi, O' Donnell M. Synthetic aperture imaging for small scale systems [ J ]. IEEE Transactions on Ultrasonics, Ferroelectrics , and Frequency Control, 1995,42 (3) : 429-442. 被引量:1