期刊文献+

大跨度叠合楼板底板试验及有限元分析

Large-span Composite Floor Bottom Slab Test and Finite Element Analysis
下载PDF
导出
摘要 针对现有的大跨度预应力叠合楼板底板刚度较小或自重较大的问题,提出了一种新型的预应力叠合楼板底板。对3块相同的简支叠合板底板进行了静载试验,分析这种底板在静载作用下的挠度、裂缝、极限承载能力等特点,并用Ansys有限元进行了模拟。试验以及模拟表明:这种底板具有较高的刚度和较强的承载能力,其挠度、开裂以及极限承载能力可按《混凝土结构设计规范》(GB 50010—2010)进行计算。 For the existing large-span composite prestressed bottom slab having small stiffness or large weight,a new type of precast prestressed slab was put forward.Based on the static loading test of the three precast prestressed simply supported slabs,the deflection,the crack,the ultimate bearing capacity were analyzed,which were simulated by the Ansys finite element.The tests and simulations showed that:this precast prestressed slab had high stiffness and well carrying capacity.The deflection,the crack and the ultimate bearing capacity can be calculated according to the code for Design of Concrete Structures (GB 50010-2010).
出处 《建材世界》 2014年第2期85-88,共4页 The World of Building Materials
关键词 预应力板 叠合板 试验 有限元 模拟 prestressed slab composited slab experiment finite element analogy
  • 相关文献

参考文献7

  • 1吴方伯,陈立,刘亚敏.预应力混凝土空心叠合板试验[J].建筑科学与工程学报,2008,25(4):88-92. 被引量:12
  • 2周鲲鹏..PK预应力双向叠合楼板的试验研究与应用[D].湖南大学,2006:
  • 3GB/T50152-2012,混凝土结构试验方法标准[S]. 被引量:14
  • 4周旺华著..现代混凝土叠合结构[M].北京:中国建筑工业出版社,1998:293.
  • 5GB50010--2010混凝土结构设计规范[S]. 被引量:1374
  • 6王新敏编著..ANSYS工程结构数值分析[M].北京:人民交通出版社,2007:554.
  • 7尚晓江,邱峰,赵海峰.Ansys结构有限元[M].北京:中国水利水电出版社,2008. 被引量:1