Density Profile and Fluctuation Measurements by Microwave Reflectometry on EAST 被引量:2

Density Profile and Fluctuation Measurements by Microwave Reflectometry on EAST
下载PDF
导出
摘要 A microwave reflectometry system operating in the V-band frequency with extraor- dinary mode polarization has been developed on the EAST tokamak. The reflectometry system, using a voltage-controlled oscillator (VCO) source driven by an arbitrary waveform generator with high temporal resolution, can operate for the density profile measurement. The result of the bench test shows that the output frequency of the VCO has a linear dependence on time. The dispersion of reflectometry system is determined and reported in this paper. The evolution of a pedestal density profile during the L-H transition is observed by the reflectometry in H-mode discharges on EAST tokamak. A frequency synthesizer is used to replace the VCO as microwave source for density fluctuation measurements. The level of density fluctuation in the pedestal shows an abrupt decrease when the plasma enters into H-mode. A coherent mode with a frequency of about 100 kHz is observed and the mode frequency decreases gradually as the pedestal evolves. A microwave reflectometry system operating in the V-band frequency with extraor- dinary mode polarization has been developed on the EAST tokamak. The reflectometry system, using a voltage-controlled oscillator (VCO) source driven by an arbitrary waveform generator with high temporal resolution, can operate for the density profile measurement. The result of the bench test shows that the output frequency of the VCO has a linear dependence on time. The dispersion of reflectometry system is determined and reported in this paper. The evolution of a pedestal density profile during the L-H transition is observed by the reflectometry in H-mode discharges on EAST tokamak. A frequency synthesizer is used to replace the VCO as microwave source for density fluctuation measurements. The level of density fluctuation in the pedestal shows an abrupt decrease when the plasma enters into H-mode. A coherent mode with a frequency of about 100 kHz is observed and the mode frequency decreases gradually as the pedestal evolves.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第4期311-315,共5页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China(Nos.11305208 and 11275234) the National Magnetic Confinement Fusion Program of China(Nos.2014GB106000 and 2014GB106003)
关键词 microwave reflectometry PEDESTAL density fluctuation EAST microwave reflectometry, pedestal, density fluctuation, EAST
  • 相关文献

参考文献13

  • 1Mazzucato E. 1998, Review of Scientific Instruments, 69:2201. 被引量:1
  • 2Laviron C, Donne A J H, Manso M E, et al. 1996, Plasma Phys. Control. Fusion, 38:905. 被引量:1
  • 3Lin Y, Irby J, Stek P, et al. 1999, Review of Scientific Instruments, 70:1078. 被引量:1
  • 4Tokuzawa T, Kawahata K, Pavlichenko R O, et al. 2001, Review of Scientific Instruments, 72:328. 被引量:1
  • 5Clairet F, Sabot R, Bottereau C, et al. 2001, Review of Scientific Instruments, 72:340. 被引量:1
  • 6Wang G, Doyle E J, Peebles W A, et al. 2004, Review of Scientific Instruments, 75:3800. 被引量:1
  • 7Meneses L, Cupido L, Sirinelli A, et al. 2008, Review of Scientific Instruments, 79:10F108. 被引量:1
  • 8Wagner F. 1982, Phys. Rev. Lett., 49:1408. 被引量:1
  • 9Liu Z X, Gao X, Zhang W Y, et al. 2012, Plasma Phys. Control. Fusion, 54:085005. 被引量:1
  • 10Xu C S, Wan B N, Li J G, eta]. 2011, Nucl. Fusion, 51:072001. 被引量:1

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部