摘要
本文详细介绍了粉煤加压气化装置中可燃有毒气体检测报警系统的设置,包括系统的配置组成,气体检测器与报警控制器的选型、布置及安装等。并对实际应用中存在的问题进行分析,提出了改进措施。
The paper introduced how to set the combustible and toxic gas detection and alarm system in coal gasiifcation process in detail, including the system conifguration, selection of the gas detector and the alarm control unit, the layout of detectors and the installation etc.. And the problems in practical application are analyzed, some improvement measures are proposed.
出处
《仪器仪表用户》
2014年第2期60-63,共4页
Instrumentation
关键词
可燃有毒气体
检测器
报警系统
combustible gas
toxic gas
detection
alarm system