期刊文献+

208例肺占位CT引导下经皮肺穿刺活检应用体会 被引量:11

Experience of 208 patients treated with CT-guided percutaneous transthoracic lung biopsy
下载PDF
导出
摘要 目的探讨提高CT引导下经皮肺穿刺活检成功率及诊断准确率。方法采用自动弹簧装载活检枪在CT引导下对208例肺部占位性病变患者进行穿刺活检。结果肺占位病变208例,穿刺成功率达98%,诊断阳性率为98%。结论做好流程每一步细节,CT引导下经皮肺穿刺活检是一种微创、快速、安全的诊断方法,对肺部占位性病变确诊价值较大。 Objective To explore how to improve the successful rate and diagnostic accuracy with CT-guided percutaneous transthoracic lung biopsy.Methods 208 patients with pulmonary occupying lesions were performed by automatic spring biopsy gun under CT-guided.Results There were 208 patients with pulmonary occupying lesions,and the punctures successful rate was 98%.The positive rate of diagnosis was 98%.Conclusion CT-guided percutaneous transthoracic lung biopsy is a safe,fast and minimally invasive diagnostic method,which has a great value in the diagnosis of pulmonary occupying lesions.
作者 赵云
出处 《临床肺科杂志》 2014年第5期815-817,共3页 Journal of Clinical Pulmonary Medicine
关键词 肺占位 肺穿刺活检 CT引导 并发症 确诊率 pulmonary occupying needle biopsy of lung CT-guided complications accuracy rate
  • 相关文献

参考文献8

二级参考文献38

  • 1刘明炯,左长京,邓小强,刘永萍.CT引导下经皮穿刺肺部小病灶活检技术的应用[J].中国临床医学影像杂志,2004,15(12):677-679. 被引量:15
  • 2龚拥军.CT窗技术的应用[J].现代医用影像学,2005,14(1):26-28. 被引量:12
  • 3张雪哲,曲凤宏.CT导引下胸部经皮细针穿刺活检的临床应用[J].中华放射学杂志,1989,23(1):47-48. 被引量:86
  • 4Laurent F,Latrabe V,Vergier B,et al.Percutaneous CT-guided biopsy of the lung:comparison between aspiration and automated cutting needle using a coaxial technique[J].Cardiovasc Intervent Radiol,2000,23(4):266-272. 被引量:1
  • 5Klein J S,Salomon G,Stewart E A.Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle:results in 122 patients[J].Radiology,1996,198(3):715-720. 被引量:1
  • 6Priola A M,Priola S M,Cataldi A,et al.Accuracy of CT-guided transthoracic needle biopsy of lung lesions:Factors affecting diagnostic yield[J].Radiol Med,2007,112(8):1142-1159. 被引量:1
  • 7Yankelevitz D F,Davis S D,Chiarella D A,et al.Pitfalls in CT-guided Transthoracic Needle Biopsy of Pulmonary nodules[J].RadloGraphics,1996,16(5):1073-1084. 被引量:1
  • 8Li H,Boiselle P M,Shepard J O,et al.Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung:comparison of small and large pulmonary nodules[J].AJR,1996,167(1):105-109. 被引量:1
  • 9Priola A M,Priola S M,Cataldi A,et al.Accuracy of CT-guided transthoracic needle biopsy of lung lesions:factors affecting diagnostic yield[J].Radiol Med (Torino),2007,112(8):1142-1159. 被引量:1
  • 10Tsai I C,Tsai W L,Chen M C,et al.CT-guided core biopsy of lung lesions:a primer[J].AJR,2009,193(5):1228-1235. 被引量:1

共引文献201

同被引文献87

引证文献11

二级引证文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部