期刊文献+

考虑多种影响因素的配电网运行风险评估 被引量:20

Distribution Network Operation Risk Assessment Considering Various Influencing Factors
下载PDF
导出
摘要 配电网故障引起的大停电事故的频频发生引发了人们对配电系统运行风险的研究。针对配电网发展过程中运行风险影响因素的不断增加,提出了一种考虑多种影响因素的配电网风险评估模型。模型中配电网停电成本的计算采用了一种新方法,该方法反映了停电频率、停电持续时间及停电电量对停电成本的综合影响,能更科学地计算出停电成本,使配电网风险评估结果更接近实际情况。最后采用蒙特卡罗法对RBTS Bus-3进行了风险评估,并与解析法的评估结果进行了对比,验证了评估方法的有效性。 The frequent blackout caused by distribution network faults has sparked research on distribution system operation risks. For the continuous increase of operation risk influencing factors in the process of distribution network development, a risk assessment model considering various influencing factors of distribution network is proposed. In the model, a new method is adopted to calculate outage cost of distribution network, which reflects the comprehensive effect of interruption frequency, interruption duration and quantity of outage on the fault cost. The method can calculate outage cost better, and the distribution network risk assessment result is closer to actual situation. Finally, the Monte Carlo method is adopted to conduct the risk assessment of RBTS Bus-3, and the evaluation results are compared with those of analytical methods to verify the effectiveness of the method.
出处 《电测与仪表》 北大核心 2014年第6期34-38,共5页 Electrical Measurement & Instrumentation
基金 中央高校科研业务项目(13QN47)
关键词 配电网 风险评估 停电成本 蒙特卡罗法 distribution network risk assessment outage cost Monte Carlo method
  • 相关文献

参考文献12

二级参考文献41

共引文献36

同被引文献186

引证文献20

二级引证文献139