期刊文献+

蚊香元素成分的LIBS检测分析 被引量:1

Measurement and Analysis on Elemental Composition of Mosquito Coil by Laser-Induced Breakdown Spectroscopy
原文传递
导出
摘要 激光诱导击穿光谱(LIBS)作为一项很有前景的元素分析技术,具有原位测量、远程监控等优势,而对蚊香样品的LIBS检测应用是一项较新的课题。为将LIBS技术实际应用于环境监测领域,实验中利用时间分辨的激光诱导击穿光谱技术对蚊香样品的激光等离子体光谱进行了测量和分析,确定出蚊香中Al、Mn、Mg、Sr、Zn、Ba、Na、Ca、Fe、Si和H的11种元素成分;基于等离子体局域热动力学平衡模型,计算了等离子体温度。利用自由定标分析方法计算了上述元素的相对含量。实验结果表明激光诱导击穿光谱技术可以用于有害元素的快捷有效检测。 Laser-induced breakdown spectroscopy(LIBS) has been used as a promising element analysis technique with the advantages of in-situ detection and remote monitoring etc. It is a relatively new task to apply LIBS to mosquito coil sample. In order to apply LIBS technique in the field related to environmental monitoring, we use time-resolved LIBS to measure and analyze mosquito coil sample. Eleven kinds of elemental composition of mosquito coil, which are A1, Mn, Mg, St, Zn, Ba, Na, Ca, Fe, Si and H, are identified. Based on local thermodynamic equilibrium (LTE) assumption, the plasma temperature is obtained. The relative concentrations of these elements are estimated by calibration-free method. The experimental result prove that LIBS can be applied to the rapid and effective detection on the harmful elements.
出处 《激光与光电子学进展》 CSCD 北大核心 2014年第3期182-188,共7页 Laser & Optoelectronics Progress
基金 国家自然科学基金(11274254 91126007 11364037 11064012)
关键词 光谱学 激光诱导击穿光谱 局域热动力学平衡 蚊香元素成分 spectroscopy laser-induced breakdown spectroscopy local thermodynamic equilibrium elemental composition of mosquito coil
  • 相关文献

参考文献8

二级参考文献91

共引文献145

同被引文献18

  • 1Celio Pasquini, Juliana Cortez, Lucas M C Silva, et al.. Laser induced breakdown spectroscopy[J]. J Braz Chem Soc, 2007, 18(3): 463-512. 被引量:1
  • 2Kyuseok Song, Yong-Ill Lee, Joseph Sneddon. Recent developments in instrumentation for laser induced breakdown spectroscopy [J]. Appl Spectrosc Rev, 2002, 37(1): 89-117. 被引量:1
  • 3M Rawat, M C Z Moturi, V Subramaninan. Inventory compilation and distribution of heavy metals in wastewater from small-scale industry area of Delhi, India[J]. J Envoron Monit, 2003, 5(6): 906-912. 被引量:1
  • 4J V Rios-Arana, E J Walsh, J L Gardea-Torresdey. Assessment of arsenic and heavy metal concentrations in water and sediments of the Rio Grande at E1 Paso-Juarez metroplex region[J]. Environ Int, 2004, 29(7): 957-971. 被引量:1
  • 5S Kanga, X Sun, X Ju, et al.. Measurement and calculation of escape peak intensities in synchrotron radiation X-ray fluorescence analysis[J]. Nucl Instrum Methods Phys Res Sect B, 2002, 192(4): 365-369. 被引量:1
  • 6M Baudelet, J Yu, M Bossu, et al.. Discrimination of microbiological samples using femtosecond laser-induced breakdown spectroscopy [J]. Appl Phys Lett, 2006, 89(16): 163903. 被引量:1
  • 7David A Cremers, Rosemarie C Chinni. Laser-induced breakdown spectroscopy-capabilities and limitations[J]. Appl Spectrosc Rev, 2009, 44(6): 457-506. 被引量:1
  • 8W T Y Mohamed. Improved LIBS limit of deteetion of Be, Mg, Si, Mn, Fe and Cu in aluminum alloy samples using a portable Echelle speetroseopy with ICCD camera[J]. Opt Laser Technol, 2007, 40(1): 30-38. 被引量:1
  • 9David A Cremers, Leon J Radziemski. Hand Book of Laser-Induced Breakdown Spectroscopy[M]. Cambridge: Cambridge University, 2013: 25. 被引量:1
  • 10Andrey M Popov, Francesco Colao, Roberta Fantoni. Enhancement of LIBS signal by spatially confining the laser-induced plasma [J]. J Anal At Spectrom, 2009, 24(5): 602-604. 被引量:1