摘要
我国已经开通运营的300km/h及以上的高速铁路,大多采用CTCS-3级列车控制系统,在日常检测中经常发现降级问题。通过对动态检测发现的降级问题进行分析,总结出无线超时导致降级的原因,积累故障处理方法、经验,不断提高故障处理业务水平、数据分析水平,确保CTCS-3级列控系统的稳定运行和安全性。
Most of system. In routine the existing high speed railways over 300km/h in C dynamic inspection, it has been detected that the adopt CTCS-3 train control train control system frequently changed from CTCS-3 to CTCS-2. Through analyzing the problem, we concluded that wireless timeout can be one of the reasons. With the accumulation of experiences in handling the failures, the level of handling failures and analyzing the data has been improved, the operation safety and steadiness of the CTCS-3 train control system will be ensured.
出处
《铁道通信信号》
2014年第3期20-22,共3页
Railway Signalling & Communication
基金
973计划课题:基于非结构化环境感知的高铁基础设施安全态势评估和故障诊断关键技术及应用2013CB329406
关键词
信号动态检测
降级
无线超时
列控系统
Signal dynamic inspection
Demote
Wireless timeout
Train control system