期刊文献+

建筑密封胶不透水性检测方法试验研究 被引量:1

Experimental study on test method of building sealants waterproof performance
下载PDF
导出
摘要 混凝土结构的伸缩缝表面处理多采用建筑密封胶,密封胶的不透水性是能否成功进行伸缩缝表面处理的关键指标,而相关规范与文献没有合适的检测方法。考虑密封胶的实际使用情况,研发了密封胶不透水性检测方法。通过试验介绍了建筑密封胶不透水性检测方法的设计、改进、试验效果及其优缺点,给出试验机制与密封胶抗压值的评定规则,发现了密封胶的破坏特征,简要分析了不同密封胶不透水性差别的原因。改进后的试验方法方便、快捷、试验结果稳定。 Building sealants waterproof performance is the key indicator to treat expansion joints surface,but we don't find appropriate method in related specifications and documents.The authors developed the test method through experiment,introduced the design,improvement,test results and the advantages and disadvantages of test method of building sealants waterproof performance,given test mechanism and assessment rules of the compressive value,discovered the damage characteristicof building sealant,and briefly analyzed the reason of difference about different sealants waterproof performance.The improved test method is convenient,fast and the test results are stable.
出处 《新型建筑材料》 2014年第3期71-74,共4页 New Building Materials
基金 河南省重点科技攻关项目(112102210403)
关键词 建筑密封胶 不透水性 试验方法 试验机制 building sealant waterproof performance test method test mechanism
  • 相关文献

参考文献8

  • 1吴剑疆,李宁博,李现社,等.南水北调中线工程总干渠衬砌分缝及嵌缝材料选择研究报告[R].江河水利水电咨询中心,2010. 被引量:1
  • 2河南建筑材料设计研究院.JC/T482--2003,聚氨酯建筑密封胶[S].北京:中国建材工业出版社,2003. 被引量:1
  • 3河南建筑材料设计研究院.JC/T482--2006,聚硫建筑密封胶[S].北京:中国建材工业出版社,2007. 被引量:1
  • 4中国化学建筑材料公司苏州防水材料研究设计所.GB/T19250-2003,聚氨酯防水涂料[S].北京:中国标准出版社,2004. 被引量:1
  • 5苏州非金属矿工业设计研究院.GB/T23446--2009,喷涂聚脲防水涂料[S].北京:中国标准出版社,2009. 被引量:1
  • 6中国化学建筑材料公司苏州防水材料研究设计所.GB/T16777-2008,建筑防水涂料试验方法[S].北京:中国标准出版社,2008. 被引量:1
  • 7中国建筑科学研究院.GB/T50082--2009,普通混凝土长期性能与耐久性能试验方法标准[S].北京:中国建筑工业出版社.2010. 被引量:1
  • 8苏州非金属矿工业设计研究院.CECS217:2006,聚硫、聚氨酯密封胶给水排水工程应用技术规程[S].北京:中国计划出版社,2007. 被引量:1