血红蛋白在银微粒修饰镍铬电极上的直接电化学行为研究

Direct Electrochemical Study of Hemoglobin on Silver Microparticles Modified Nichrome Substrate Electrode
下载PDF
导出
摘要 以镍铬合金为基体电极,采用电沉积技术制备了银微粒电极.用扫描电镜表征了基体电极电沉积前后的形貌特征.利用循环伏安技术研究了该银微粒电极对血红蛋白(Hb)的直接电化学行为.实验结果表明具有立体结构的银微粒对血红蛋白具有良好的电催化活性,实现了血红蛋白分子的直接电子转移.在1×10^-6mol·L^-1~2×10^-5mol·L^-1范围内,Hb氧化峰电流和Hb浓度有较好的线性关系.该银微粒电极制备简单,性能稳定,使用寿命相对较长,可有望用于蛋白质的分析测定和实现Hb在第三代生物传感器的开发和应用. A novel silver microparticles electrode was fabricated on nichrome substrate by using cyclic voltammetry tech- nique and its morphology was characterized by scanning electron microscopy. The electrochemical behavior of hemoglobin(Hb) was also investigated on silver microparticles electrode, Experimental results indicated that three-dimensional silver microparti- cles showed a good electrocatalytic activity and achieve direct electron transfer of hemoglobin. The oxidation peak currents of Hb were linear to its concentration from 1 )〈 10-6 mol ~ L-1 to 2 〉( 10-5 mol ~ L-1. The fabrication method of silver microparti- cles electrode was simple and possessed stable performance as well as long working life. The modified electrode is expected to use as an promising electrode material towards the detection of protein and development of the third biosensors.
出处 《河南师范大学学报(自然科学版)》 CAS 北大核心 2014年第1期77-81,共5页 Journal of Henan Normal University(Natural Science Edition)
基金 国家自然科学基金(20675026)
关键词 镍铬合金 银微粒电极 血红蛋白 直接电化学 nichrome substrate silver microparticles electrode hemoglobin(Hb) direct electrochemistry
  • 相关文献

参考文献25

  • 1Xiao Y. Iu H X. Chen H Y. Hydrogen Peroxide Sensor Based on Horseradish Peroxidase-Labeled Au Colloids Immobilized on Gold Electrode Surface by Cysteamine Monolayer [J]. Anal Chim Acta.1999. 391: 73-82. 被引量:1
  • 2Zhang Z. Chouchane S. Magliozzo R S. et al, Direct Voltammetry and Catalysis with Mycobacterium Tuberculosis Catalase-Peroxidase. Peroxidases , and Catalase in Lipid Films[J]. Anal Chem.2002.74:163-170. 被引量:1
  • 3Shen L. Hu N F. Heme Protein Films with Polyamidoamine Dendrimer , Direct Electrochemistry and Electrocatalysis[J]. Anal Biochem , 2004.1608(1) :23-33. 被引量:1
  • 4Liu H Y. Wang L W. Hu N F. Direct Electrochemistry of Hemoglobin in Biomembrane-like DHP-PDDA Polyion-Surfactant Composite Films[J]. Electrochim. Acta.2002.47(15) :2515-2523. 被引量:1
  • 5Ye J N, Baldwin R P. Catalytic Reduction of Myoglobin and Hemoglobin at Chemically Modified Electrodes Containing Methylene Blue [J]. Anal Chern. 1988 ? 60(20) : 2263-2268. 被引量:1
  • 6Dong S Y. Zhang PH. Liu H, et al. Direct Electrochemistry and Electrocatalysis of Hemoglobin in Composite Film Based on Ionic Liquid and NiO Microspheres with Different Morphologies]']']. Biosens. Bioelectron.2011.26(10) :4082-4087. 被引量:1
  • 7Fan C H. Wang H Y. Sun S. et al. Electron-transfer Reactivity and Enzymatic Activity of Hemoglobin in a SP Sephadex Membrane[J]. Anal Chem.2001, 73(13) :2850-2854. 被引量:1
  • 8Garabagiu S. Mihailescu G. Simple Hemoglobin-gold Nanoparticles Modified Electrode for the Amperometric Detection of Acrylamide [J]. J Electroanal Chem,2011.659(2) :196-200. 被引量:1
  • 9Yue Z X. Yu Y Z, Yang X. et al. Preparation of Poly (Vinylpyrrolidoner-Protected Prussian Blue Nanoparticles-Modified Electrode and Its Electrocatalytic Reduction for Hemoglobin[J]. Anal Chim Acta.2005.546(2):139-146. 被引量:1
  • 10XU Y X. Hu C G. Hu S S. A Hydrogen Peroxide Biosensor Based on Direct Electrochemistry of Hemoglobin in Hb-Ag Sol Films[J]. Sensor Actuat B Chem.2008.130(2) :816-822. 被引量:1